SERVICE MANUAL
ENGLISH
RS 501
33019746(2)2010-03
117
IMPIANTO IDRAULICO
HYDRAULIC SYSTEM OIL PRESSURE CHECK AT THE SUCTION FAN PUMP
NOTE
This check is necessary in case of malfunction of the suction fan.
Preliminary operations
Drive the machine on a solid and level ground, then engage the parking brake with the lever (66).
1.
Turn the ignition key (76) to OFF position and remove it.
2.
Remove the screws and the right panel (22) on the right side of the cab.
3.
Connect a pressure gauge (A), with a minimum scale of 3,626 psi (250 Bar) equipped with capillary tube (B), to the pressure
4.
inlet (C).
Measure the suction fan pump pressure according to the following procedure.
5.
Pressure measurement
Start the machine and run the engine at maximum speed (as shown in the Instructions for use Manual). In this condition,
6.
turn the lever (D) to “OPT” position and check that the pressure measured by the pressure gauge (A) is 3,191 psi (220 Bar)
approximately.
If the pressure is normal, disengage the lever (D) and turn off the machine.
•
If the pressure is higher or lower, it can be adjusted according to the following procedure, while keeping the machine
•
accelerated and the lever (D) engaged.
Pressure adjustment
Unscrew the cap (G).
7.
Loosen the locknut (E) and slightly turn the internal threaded dowel (F) to adjust the pressure. If the pressure cannot be
8.
adjusted to normal values, probably the pump needs to be replaced (see the procedure in the relevant paragraph).
Disengage the lever (D) and turn off the machine.
9.
Tighten the locknut (E) and screw down the cap (G).
10.
Reset
Perform steps 3 and 4 in the reverse order.
11.
Summary of Contents for ADVANCE RS 501
Page 2: ...RS 501 Nilfisk 502 SERVICE MANUAL ENGLISH 33019746 2 2010 03...
Page 3: ......
Page 57: ...ENGLISH SERVICE MANUAL 54 33019746 2 2010 03 RS 501 STERZO...
Page 146: ......
Page 147: ......
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......