ENGLISH
SERVICE MANUAL
48
33019746(2)2010-03
RS 501
IMPIANTO IDRICO
NOZZLE AND FILTER CLEANING
WARNING!
Protect body parts (eyes, hair, hands, etc.) properly, when performing cleaning procedures using compressed
air or water gun.
Preliminary operations
Engage the parking brake with the lever (66).
1.
Turn the ignition key (76) to OFF position and remove it.
2.
Cleaning of nozzles and fi lters on brooms
Unscrew the ring nuts (A).
3.
Clean the nozzles (B) and fi lters (C) with compressed air. Remove calcium deposits. If necessary, replace the fi lters (C).
4.
Install the fi lters and nozzles, and secure them with the ring nuts. Nozzle holes must be directed down when tightening.
5.
Cleaning of nozzles inside the suction inlet
On both sides of the suction inlet (D), remove the screws (E) together with the nozzles (F).
6.
Clean the nozzles (F) and screws (E) with compressed air. Remove calcium deposits.
7.
Assemble the components in the reverse order of disassembly.
8.
Cleaning of nozzle and fi lter in the rear suction pipe
Remove the screw (G), the nozzle (H) and the fi lter (I).
9.
Clean the nozzle (H) and fi lter (I) with compressed air. Remove calcium deposits. If necessary, replace the fi lter (I).
10.
Assemble the components in the reverse order of disassembly.
11.
Summary of Contents for ADVANCE RS 501
Page 2: ...RS 501 Nilfisk 502 SERVICE MANUAL ENGLISH 33019746 2 2010 03...
Page 3: ......
Page 57: ...ENGLISH SERVICE MANUAL 54 33019746 2 2010 03 RS 501 STERZO...
Page 146: ......
Page 147: ......
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......