ENGLISH
SERVICE MANUAL
142
33019746(2)2010-03
RS 501
IMPIANTO ELETTRICO
CONTROL PANEL DISPLAY FUNCTIONS (Continues)
Maintenance interval reset
5.
The Service Center must reset the maintenance intervals at 200 hours (MA_0) and 800 hours (MA_1) on the display, as shown
below:
Press and hold the display scroll button (41) on the “STORE” position then turn the ignition key (76) to the fi rst position.
•
Press and hold the display scroll button (41) for a few seconds until the password entering screen (A) is shown.
•
Insert the password 376 by pressing the push-button (41) on the “SEL” position to increase the number and on the
•
“STORE” position to shift the cursor to the next digit. When the number 376 is set, press and hold the push-button (41) on
the “STORE” position until the fi rst screen is shown.
Proceed as shown in the previous paragraph until the MAINT.01 is shown.
•
Press the push-button (41) on the “SEL” position to shift the cursor (B) to the maintenance interval which has to be reset (C
•
or D).
NOTE
The pencil shaped cursor indicates the possibility to modify.
Press and hold the push-button (41) on the “STORE” position until the value returns to 200 or 800 hours, depending on the
•
maintenance which has been performed.
B
C
D
PASSWORD
A
S341068