ENGLISH
SERVICE MANUAL
112
33019746(2)2010-03
RS 501
IMPIANTO IDRAULICO
SUCTION FAN DISTRIBUTOR REMOVAL/INSTALLATION
CAUTION!
This procedure must be performed with the hopper (3) fully lowered.
CAUTION!
If necessary, remove the bonded sealing washers and replace them.
Remove the screws and the right panel (22) on the right side of the cab.
1.
Disconnect all the hoses from the suction fan distributor (A) and plug them immediately.
2.
WARNING!
Hydraulic system oil is highly corrosive, wear rubber gloves.
Loosen the locknut (C) and remove the lever (B).
3.
Remove the screws (D), then remove the distributor (A).
4.
If necessary, remove the fi ttings and the distributor at the workbench.
5.
Assemble the components in the reverse order of disassembly.
6.
Check the hydraulic system oil level (see the procedure in the relevant paragraph).
7.
Check the hydraulic system oil pressure at the suction fan pump (see the procedure in the relevant paragraph).
8.
A
C
B
D
D
S341052