![ADTRAN 1202011L1 User Manual Download Page 86](http://html1.mh-extra.com/html/adtran/1202011l1/1202011l1_user-manual_2854690086.webp)
Chapter 11. Testing and Troubleshooting
11-2
DSU III AR User Manual
61202011L1-1
Initiating a Test
To initiate tests, perform the following steps:
The example in Figure 11-2 shows the menu path for initiating a
local DTE and Loop test.
Once a test is initiated
P
LEASE
W
AIT
displays briefly and is
followed by the status screen.
Step Action
1
To select T
EST
from the main menu, press
2
; then press
Enter
.
2
Specify L
OCAL
, R
EMOTE
, or AR testing by selecting the
corresponding number; then press
Enter
.
3
Use the up and down arrows to view test options.
4
Select a test from the available options by pressing the
corresponding number and then
Enter
.
1=DTE & LOOP (LL)
2=LOOP ONLY (RT)
1=LOCAL UNIT
3=DTE ONLY
4=DTE WITH TP
5=TEST PATTERN
2=TEST
6=SELF TEST
2=REMOTE UNIT
ENTER TEST UNIT
ADDRESS: 0
Figure 11-2. Initiating a Test
Summary of Contents for 1202011L1
Page 1: ...DSU III AR Data Service Unit User Manual Part Number 1202011L1 61202011L1 1C May 2001...
Page 18: ...Table of Contents xviii DSU III AR User Manual 61202011L1 1...
Page 24: ...List of Tables xxiv DSU III AR User Manual 61202011L1 1...
Page 72: ...Chapter 6 Configuring DTE Options 6 18 DSU III AR User Manual 61202011L1 1...
Page 82: ...Chapter 9 Manual Command 9 4 DSU III AR User Manual 61202011L1 1...
Page 110: ...Chapter 11 Testing and Troubleshooting 11 26 DSU III AR User Manual 61202011L1 1...
Page 130: ...Appendix B AT Commands B 12 DSU III AR User Manual 61202011L1 1...
Page 134: ...Appendix C Default Configuration Profiles C 4 DSU III AR User Manual 61202011L1 1...
Page 136: ...Appendix D EIA 232 Connector D 2 DSU III AR User Manual 61202011L1 1...
Page 140: ...Appendix E DSU to DSU Tail Circuit E 4 DSU III AR User Manual 61202011L1 1...
Page 144: ...Appendix F Specifications Summary F 4 DSU III AR User Manual 61202011L1 1...
Page 158: ...Appendix H Glossary H 10 DSU IV ESP User Manual 61204011L1 1...