Chapter 2. Installation
2-4
DSU III AR User Manual
61202011L1-1
Network Interface Connection
The DSU III AR has an eight-position modular jack labeled
T
ELCO
.
The connector is used for connecting to the network when the unit
is configured for either dedicated or switched operation. The pin
assignments for the telco connector are listed in Table A-1 on page
A-1.
DTE Data Connection/Primary DTE
The primary DTE rate is configured from the front panel. The
primary DTE can operate in asynchronous or synchronous modes
The primary DTE should be connected to either the EIA-232 DTE
connector or the CCITT V.35 DTE connector.
The maximum cable lengths recommended are 50 feet for the EIA-
232. The pin assignments for the primary EIA-232 connector are
shown in Table A-2 on page A-2. The EIA-232 connector works up
to 56 kbps with a low capacitance cable or with the external
transmit clock option selected.
For the CCITT V.35, the maximum cable lengths are 100 feet. The
pin assignments for the V.35 are shown in Table A-3 on page A-3.
The V.35 connector is recommended for use with data rates above
19.2 kbps.
Secondary Channel Connection
If used, the secondary DTE should be connected to the auxiliary
EIA-232 connector. The pinout for the connector is shown in Table
A-4 on page A-4.
To prevent possible radio frequency interference emissions, a shielded ca-
ble is required.
Summary of Contents for 1202011L1
Page 1: ...DSU III AR Data Service Unit User Manual Part Number 1202011L1 61202011L1 1C May 2001...
Page 18: ...Table of Contents xviii DSU III AR User Manual 61202011L1 1...
Page 24: ...List of Tables xxiv DSU III AR User Manual 61202011L1 1...
Page 72: ...Chapter 6 Configuring DTE Options 6 18 DSU III AR User Manual 61202011L1 1...
Page 82: ...Chapter 9 Manual Command 9 4 DSU III AR User Manual 61202011L1 1...
Page 110: ...Chapter 11 Testing and Troubleshooting 11 26 DSU III AR User Manual 61202011L1 1...
Page 130: ...Appendix B AT Commands B 12 DSU III AR User Manual 61202011L1 1...
Page 134: ...Appendix C Default Configuration Profiles C 4 DSU III AR User Manual 61202011L1 1...
Page 136: ...Appendix D EIA 232 Connector D 2 DSU III AR User Manual 61202011L1 1...
Page 140: ...Appendix E DSU to DSU Tail Circuit E 4 DSU III AR User Manual 61202011L1 1...
Page 144: ...Appendix F Specifications Summary F 4 DSU III AR User Manual 61202011L1 1...
Page 158: ...Appendix H Glossary H 10 DSU IV ESP User Manual 61204011L1 1...