background image

WARNINGS AND GENERAL SAFETY PRECAUTIONS 

 

Fully 

READ 

and 

UNDERSTAND

 all instructions 

carefully before beginning installation. 

 

ALL WARNINGS OUTLINED IN THIS MANUAL MUST BE STRICTLY  

ADHERED TO BY THE INSTALLER AND HOMEOWNER.   

FAILURE TO FOLLOW 

these installation instructions will  

VOID THE WARRANTY 

and may cause a serious 

FIRE HAZARD.

 

DO NOT modify your fireplace in any way.

 

Any modification will void the warranty and 
create a potential fire hazard. 

Before burning your first fire, fully read the 

“Homeowners Operation Manual”.

 

Combustion Air Intake 

of fireplace must be 

kept clear of debris at all times. 

This fireplace is to be installed ONLY by a construction industry licensed contractor. Any permits and 
construction industry inspections required for installation should be obtained by this contractor. 

Do not 

store

 or 

use 

flammable liquids or  

aerosols near this fireplace. 

Never leave the fireplace burning while unat‐
tended. 

Children should never be left unattended 
while the fireplace is in use. 

WARNING

: Only use approved chimney and 

termination systems outlined in this manual. 

WARNING

: This fireplace is 

NOT

 designed for 

wall termination. Fireplace must be vented 
vertically. 

 

IMPORTANT: 

THESE INSTRUCTIONS MUST BE LEFT  

WITH HOMEOWNER 

 

Summary of Contents for KIVA 18 Ornito

Page 1: ...lar steel and diamond mesh frame The frame is finished with stucco after installation C AIR COOLED CHIMNEY Lightweight stainless steel double walled air cooled chimney is used for venting the fireplac...

Page 2: ...2 This page intentionally left blank...

Page 3: ...Manual Combustion Air Intake of fireplace must be kept clear of debris at all times This fireplace is to be installed ONLY by a construction industry licensed contractor Any permits and construction i...

Page 4: ...4 This page intentionally left blank...

Page 5: ...Fireplace Layout 10 11 Fireplace Pedestal 11 2 Firebox Installation 12 Firebox Assembly 12 Door Frame 13 Anchor Plate 13 3 Chimney Installation 14 Installing the Chimney Pipe 14 17 Outside Air Kit In...

Page 6: ...___________ Dealership Purchased at ______________________________________ Dealership Phone __________________________________________ Date Purchased ________________ Date Installed __________________...

Page 7: ...TO COMBUSTIBLES SIDES BACK 1 FACE All framing along firebox face must be non combustible HEARTH EXTENTION 18 CHIMNEY 2 KIVA24 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 24 25 1 4 34 25 44 52 2...

Page 8: ...00 WARNING B Vent Chimney should never be used when solid fuels are to be burned TABLE 1 chimney requirements KIVA30 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 30 30 40 27 1 4 48 1 2 56 1 2 28...

Page 9: ...ural Gas and 39 700 for Liquid Propane STUB OUT Before the Adobelite firebox is installed gas lines should be run into the area where the fireplace will be in stalled A Keyed Gas Shutoff Valve is requ...

Page 10: ...an Electrical Box and Wall Switch or remote control receiver for fireplace control in the wall at the desired location Refer to FIG 1 on page 9 to locate the minimum distance from the corner that the...

Page 11: ...shown in FIG 6 or any other combination of concrete blocks can also be used as long as the overall height is 12 1 Two columns of CMU s should be positioned with the front edge of the blocks against th...

Page 12: ...eces will meet and align the back and sides of the pieces 5 FRONT ARCH Apply refractory mortar to the front edges of the Lower and Upper Back pieces and to the top of the Front Arch sec tion Place the...

Page 13: ...refractory mortar to the top of firebox where the Anchor Plate will sit Align the back edge of the Anchor Plate opening with opening in the firebox top section Secure the Anchor Plate using four dia x...

Page 14: ...The Starter Collar is used to support the outer chimney section while the Anchor Plate collar supports the inner chimney Attach the legs of the Starter Collar to the Anchor Plate with the supplied 12...

Page 15: ...ensions A and E in Layout charts Pages 10 11 Firmly push both the in ner and outer pipes into the Starter Elbow until they snap lock into place 14 RETURN ELBOW Position the Return Elbow so that the ch...

Page 16: ...Firestop Spacers are required at each point where the chimney penetrates a floor or ceil ing joist space Attach Firestop Spacer to joist using wood screws If the chimney pipe passes through a framed o...

Page 17: ...tion air to the firebox therefore not using air from the interior of the house as well as cooling the gas control system 20 4 HOLE FIG 20 1 OUTSIDE AIR VENT EXTERIOR WALL FIG 21 ALUMINUM FLEX DUCT 21...

Page 18: ...UAL IS NOT FOLLOWED EXACTLY A FIRE OR EPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE 22 ATTACHING BURNER PAN AND PILOT Screw the fe male flare fitting on the end of the su...

Page 19: ...g Next cut several strips of diamond lath mesh 16 wide Place the lath strips against the inside Front Arch even with the Door Frame FIG 24 Using 15 8 washer head screws attach the lath to the Front Ar...

Page 20: ...ay not contain sand and cement Many indoor plasters are gypsum based Apply the 2nd coat using a trowel and then smooth out the plaster using water and a float or sponge When complete the 2nd coat will...

Page 21: ...ear the supplied Glowing Embers into dime sized pieces Place the pieces all around the burner holes on top of the burner pan making sure not to cover the burn holes where the gas will come out of See...

Page 22: ...T WHAT TO DO IF YOU SMELL GAS 1 Shut off gas to fireplace 2 Extinguish and flame 3 Go to a phone outside your home and call your gas supplier If you can t reach your gas supplier call the Fire Departm...

Page 23: ...a Frame hearth extension and are available in lengths of 2 to 10 Specify left or rights side when ordering Wood Storage Bin The Wood Storage Bin has an interior size of 24 wide x 12 high x 16 deep It...