background image

12 

1)  BASE 

–Spread a thin layer of concrete mortar or construction adhesive 

on the top of the firebox pedestal. Place the firebox base on the pedes‐
tal.  Using the layout sketch, align the front of the base with the firebox 
base  line  and  center  the  firebox  along  the  center  line.  Make  sure  the 
Base is level.  

FIREBOX ASSEMBLY 

2)  LOWER  BACK 

–Apply  a  5”  wide  thin  layer  of  the  included  refractory 

mortar to the  outside top edge of the base where the Lower Back will 
rest.  Place  the  Lower  Back  in  place  and  rotate  the  piece  slightly  back 
and  forth  to  squish  the  mortar  into  place.  Align  the  back  and  sides  of 
the Lower Back and Base. 

3)  UPPER  BACK  (MODELS  KIVA24  AND  KIVA30  ONLY) 

–  Following  the 

above procedure, spread a layer of refractory mortar and place the Up‐
per  Back  section  on  top  of  the  Lower  Back.  Again,  align  the  back  and 
sides of the pieces. 

6)  TOP 

–Now install the top section of 

the  fireplace.  Again,  spread  a  thin 
layer  of  refractory  mortar  where 
the  pieces  will  meet,  and  align  the 
back and sides of the pieces. 

5)  FRONT  ARCH 

–Apply  refractory 

mortar  to  the    front  edges  of  the 
Lower  and  Upper  Back  pieces  and 
to  the  top  of  the  Front  Arch  sec‐
tion. Place the Front Arch into place 
and  attach  using  four 

1

/

4

”  x  6”  Lag 

Bolts.  Avoid  placing  any  weight 
onto the Manifold before the bolts 
are attached. 

 

6 –

Top 

2 –

Lower Back 

3 –

Upper Back 

 

 

1 –

Base 

6” Bolts

 

5 –

Front Arch 

 

4) MANIFOLD AND GAS SYSTEM 

– Apply a 1” wide layer of refractory mor‐

tar  to  the  upper  face  of  the  fireplace  base.  Position  the  Manifold  so 
that the face of the Manifold is against the face of the base, and the L‐
Bracket (that supplies combustion air) is resting on the firebrick surface 
of the Base. The Burn Pan and Kiva Grate will rest on the Base towards 
the back.  Using the supplied ¼” x 3” lag bolts, bolt the manifold to the 
Base. The heads of the bolts will pass through the face of the manifold 
and tighten against the back of the manifold. 

Do Not Over‐tighten the 

Bolts! 

Using your finger, apply refractory mortar to all the seams where 

the manifold touches the Base. 

4 –

Manifold and Gas System 

¼” dia. x 3” lag bolts 

L– Bracket 

 

Burn Pan and 
Kiva Grate 

Summary of Contents for KIVA 18 Ornito

Page 1: ...lar steel and diamond mesh frame The frame is finished with stucco after installation C AIR COOLED CHIMNEY Lightweight stainless steel double walled air cooled chimney is used for venting the fireplac...

Page 2: ...2 This page intentionally left blank...

Page 3: ...Manual Combustion Air Intake of fireplace must be kept clear of debris at all times This fireplace is to be installed ONLY by a construction industry licensed contractor Any permits and construction i...

Page 4: ...4 This page intentionally left blank...

Page 5: ...Fireplace Layout 10 11 Fireplace Pedestal 11 2 Firebox Installation 12 Firebox Assembly 12 Door Frame 13 Anchor Plate 13 3 Chimney Installation 14 Installing the Chimney Pipe 14 17 Outside Air Kit In...

Page 6: ...___________ Dealership Purchased at ______________________________________ Dealership Phone __________________________________________ Date Purchased ________________ Date Installed __________________...

Page 7: ...TO COMBUSTIBLES SIDES BACK 1 FACE All framing along firebox face must be non combustible HEARTH EXTENTION 18 CHIMNEY 2 KIVA24 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 24 25 1 4 34 25 44 52 2...

Page 8: ...00 WARNING B Vent Chimney should never be used when solid fuels are to be burned TABLE 1 chimney requirements KIVA30 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 30 30 40 27 1 4 48 1 2 56 1 2 28...

Page 9: ...ural Gas and 39 700 for Liquid Propane STUB OUT Before the Adobelite firebox is installed gas lines should be run into the area where the fireplace will be in stalled A Keyed Gas Shutoff Valve is requ...

Page 10: ...an Electrical Box and Wall Switch or remote control receiver for fireplace control in the wall at the desired location Refer to FIG 1 on page 9 to locate the minimum distance from the corner that the...

Page 11: ...shown in FIG 6 or any other combination of concrete blocks can also be used as long as the overall height is 12 1 Two columns of CMU s should be positioned with the front edge of the blocks against th...

Page 12: ...eces will meet and align the back and sides of the pieces 5 FRONT ARCH Apply refractory mortar to the front edges of the Lower and Upper Back pieces and to the top of the Front Arch sec tion Place the...

Page 13: ...refractory mortar to the top of firebox where the Anchor Plate will sit Align the back edge of the Anchor Plate opening with opening in the firebox top section Secure the Anchor Plate using four dia x...

Page 14: ...The Starter Collar is used to support the outer chimney section while the Anchor Plate collar supports the inner chimney Attach the legs of the Starter Collar to the Anchor Plate with the supplied 12...

Page 15: ...ensions A and E in Layout charts Pages 10 11 Firmly push both the in ner and outer pipes into the Starter Elbow until they snap lock into place 14 RETURN ELBOW Position the Return Elbow so that the ch...

Page 16: ...Firestop Spacers are required at each point where the chimney penetrates a floor or ceil ing joist space Attach Firestop Spacer to joist using wood screws If the chimney pipe passes through a framed o...

Page 17: ...tion air to the firebox therefore not using air from the interior of the house as well as cooling the gas control system 20 4 HOLE FIG 20 1 OUTSIDE AIR VENT EXTERIOR WALL FIG 21 ALUMINUM FLEX DUCT 21...

Page 18: ...UAL IS NOT FOLLOWED EXACTLY A FIRE OR EPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE 22 ATTACHING BURNER PAN AND PILOT Screw the fe male flare fitting on the end of the su...

Page 19: ...g Next cut several strips of diamond lath mesh 16 wide Place the lath strips against the inside Front Arch even with the Door Frame FIG 24 Using 15 8 washer head screws attach the lath to the Front Ar...

Page 20: ...ay not contain sand and cement Many indoor plasters are gypsum based Apply the 2nd coat using a trowel and then smooth out the plaster using water and a float or sponge When complete the 2nd coat will...

Page 21: ...ear the supplied Glowing Embers into dime sized pieces Place the pieces all around the burner holes on top of the burner pan making sure not to cover the burn holes where the gas will come out of See...

Page 22: ...T WHAT TO DO IF YOU SMELL GAS 1 Shut off gas to fireplace 2 Extinguish and flame 3 Go to a phone outside your home and call your gas supplier If you can t reach your gas supplier call the Fire Departm...

Page 23: ...a Frame hearth extension and are available in lengths of 2 to 10 Specify left or rights side when ordering Wood Storage Bin The Wood Storage Bin has an interior size of 24 wide x 12 high x 16 deep It...

Reviews: