Installation
•
9
Channel No.
Internal -5V
( Default)
Internal -10V
CH1
JP3
-10
-5
JP3
-10
-5
CH2
JP7
-10
-5
JP7
-10
-5
Figure 2.4 Internal Reference Voltage Setting
If users choose the external reference, both AC and DC voltage sources
can be used by the external reference, and the maximum input voltage is
+/- 10V. The voltage sources can be input through Pin 3 of CN1 and CN2
connectors.
2.6.2 Output Range Setting
The output voltage range of ACL-6128 can be set either
Bipolar
or
Unipolar
. The jumpers, JP1 and JP5 ( for CH1), and JP2 and JP9 ( for
CH2) are used for the setting and illustrated as Figure 2.5 below:
Channel No.
Unipolar
( Default )
Bipolar
CH1
JP1
JP5
UP
BP
UP
BP
JP1
JP5
UP
BP
UP
BP
CH2
JP2
JP9
UP
BP
UP
BP
JP2
JP9
UP
BP
UP
BP
Figure 2.5 Ouput Range Setting