Installation
•
11
2.7 Current Sink Range Setting
Not only the voltage output, the ACL-6128 also provide either 0-20mA or
4-20 mA current sink. In order to use the current sink range, you must set
the output voltage to
unipolar
. The jumper JP6 is corresponding to CH1,
and JP10 is used with CH2. The illustration Figure 2.7 below shows the
settings for the ACL-6128's current sink range.
Channel No.
4-20 mA
( Default )
0-20 mA
CH1
JP6
0
4
JP6
0
4
CH2
JP10
0
4
JP10
0
4
Figure 2.7 Current Sink Setting
Note :
The current sink can only be used when the output voltage range set as
internal
reference with -5V
and
unipolar mode.
Summary of Contents for ACL -6128
Page 1: ...N u D A Q A C L 6 1 2 8 2 Channel Isolated 12 bit Analog Output Card U s e r s G u i d e...
Page 4: ......
Page 8: ......
Page 33: ...Calibration 25...