10
•
Installation
2.6.3 Summary
According to the reference source and output range settings, users can
follow the below table to configure the output voltage of CH1 and CH2 for
different situations.
( JP1, JP3, and JP5 are for CH1; JP2, JP7, and JP9 are for CH2)
Jumper
Output Range
JP3 for CH1
JP7 for CH2
JP1&JP5 for CH1
JP2 & JP9 for CH2
0 to +5V
Unipolar
(Default)
JP3/JP7
-10
-5
JP1
JP5
UP
BP
UP
BP
0V to +10V
Unipolar
JP3/JP7
-10
-5
JP1
JP5
UP
BP
UP
BP
-5V to +5V
Bipolar
JP3/JP7
-10
-5
JP1
JP5
UP
BP
UP
BP
-10V to +10V
Bipolar
JP3/JP7
-10
-5
JP1
JP5
UP
BP
UP
BP
Figure 2.6 Output Range Summary