13
2.9 Signal Connection
A correct signal connection is quite important to send data accuracy. In
this section, a helpful information for how to make proper signal
connection when the ACL-6128 is used.
2.9.1 Voltage Output Connection
Amp.
Load
V.OUT
A.GND
ACL-6128 Side
External
Side
l oa d
R
2.9.2 Current Sink Connection
Amp.
I.SINK
A.GND
ACL-6128 Side
External
Side
+
-
Power
Supply
-
+
R
Load
Note :
For 4-20mA current sink mode, the output range should be set as
Internal Reference with -5V
and
Unipolar mode
.