STEP 3: FINISH PLUMBING
3A.
Finish the supply water line installation. For both the Hot and Cold, use 1/2” x 3/8” (copper tube
OD x ID) 90-degree Angle Compression Water Supply Shutoffs and Trim Bezels. (Not Supplied)
3B.
Shampoo Bowl: Install the faucet, hose and all related pieces to the shampoo bowl per the
instructions provided from the manufacturer.
3C.
If you have a Comfort Fit bowl with an
integral molded bracket, mount it directly to
the Front Panel with three ¼-20 x 2” bolts
provided.
If you have a bowl with a separate bracket,
Install the sink leveling bolt onto the sink
mounting bracket, then mount the shampoo
bowl on the Sink Mounting Bracket. Be
sure to level the sink to the Front Panel,
secure its position using the leveling bolt
under the sink and properly secure it by
tightening the nut under each side of the
bowl.
3D.
elevate the shampoo bowl to its
highest position. Mount the Drain Support
Bracket assembly onto the mounting panel
using the two ¼-20” x ¾” bolts provided.
Make sure the two 5/16” bolts holding the
Drain Clamp Bracket to the Drain
Support Bracket & the hose clamps are
loose enough to make adjustments.