Adjust-A-Sink® E140 System by Accessible Systems Inc. | Minneapolis, MN | 612-238-4600 | www.adjustasink.com
11 of 25
3K. INITIAL DRAIN ALIGNMENT TESTING PROCEDURE
•
Raise and lower the unit all the way up and down several times to be sure it is operating
properly, without binding
before and after
connecting it to the building drain.
•
It is important that the lift system reaches its limits
prior
to the drain extending to its full range.
You should be able to vertically move the center section of the drain by at least ¼” at both the
upper and lower stops of the lift system. Make any minor adjustments that are needed to keep
the lift system from binding and to ensure that the lift system reaches its end of travel limit prior
to the 3-Stage Telescopic Drain Assembly extending to its full range.
•
Now ensure that all of the parts are tightened securely and glue the P-trap to building drain.
Care should be used to ensure you do NOT cause strain or binding on the vertical 3-Stage
Telescoping Drain Assembly.
3L.
Connect the provided flexible Water
Supply Lines to both the faucet and the
water supply shutoffs. Use care and good
judgment when installing the flexible lines
so they are free and unobstructed when
traveling with the elevating shampoo bowl.
Start with the unit in its highest position and
secure with tubing clamps and #8 screws
provided. It is recommended that the two
flexible lines be secured to the front panel and
drain bracket such that they have just a little
slack at the uppermost position.
Little to no
supply hose
slack in
highest
position