ADI LT boiler – Technical manual
Page
18
10.6 AVAILABLE PARAMETERS THAT CAN BE ADJUSTED BY THE FINAL USER
•
Press the button T6 or T7
, to accede directly to the programming level “final user”.
•
Select the required line by pressing the buttons T6 and T7,
, the display will show “Pxxx”
•
Adjust the required value by pressing the buttons T8 and T9,
.
The adjusted value will be saved when changing line.
•
Press the button T2 to get out of the programming level. Changes won’t be saved.
•
Press the button T10 to get out of the programming level. Changes will be saved.
If nothing changes after 8 minutes or any other button has been pressed, you will come back to the initial
display and changes won’t be saved.
If you go to another level or line, changes will be automatically saved.
Line
Function
Adjustment
range
Unit
Resolution Value
by
default
1
Current time
0 ... 23:59
h / min 1 min
---
5
Boiler reduced set-up temperature
TRN
ºC
0.5
69.0
11
Time program Heating circuit 1: phase 1 start-up time
00:00... 24:00
hh:mm 10 min
06:00
12
Time program Heating circuit 1: phase 1, stop time
00:00... 24:00
hh:mm 10 min
22:00
13
Time program Heating circuit 1: phase 2, start-up time
00:00... 24:00
hh:mm 10 min
24:00
14
Time program Heating circuit 1: phase 2, stop time
00:00... 24:00
hh:mm 10 min
24:00
15
Time program Heating circuit 1: phase 3 start-up time
00:00... 24:00
hh:mm 10 min
24:00
Time
programming
16
Time program Heating circuit 1: phase 3 stop time
00:00... 24:00
hh:mm 10 min
24:00
31-36
Not available
: Time programs of D.H.W.S. circuit
00:00... 24:00
hh:mm 10 min
06:00
45
Standard time programs for heating
(press simultaneously T8 and T9,
,
during 3 seconds)
No / Yes
----
-----
No