Table 7-5: Minimum exposure time. Please note that the minimum value in the ExposureTime feature is 1 µs.
Therefore the minimum exposure time equals the FOT + 1 µs.
SensorBitDepth t_sens (µs)
Min. exposure time (µs)
8
15.41
15.41 + 1 = 16.41
10
15.3
15.3 + 1 = 16.3
Table 7-6: Integration time for the SyncControlMode.
SensorBitDepth
Actual integration time [µs]
8-bit
AcquisitionFramePeriod – FOT + 15.41
10-bit
AcquisitionFramePeriod – FOT + 15.3
N+1
N+1
N
Exposure time
N
Frame output
N+2
N+2
N
Exposure time
N
Frame output
N+1
N+2
N+2
N+1
N
Exposure time
N
Frame output
N+1
N+2
N+1
N
Exposure time
N
Frame output
N+2
N+1
N+1
N+2
AcquisitionFramePeriod
ExposureTime
Timed
Trigger
TriggerWidth
SyncControlMode
TimedTriggerControl
N+3
N+4
N+3
N-1
Figure 7-4: Exposure modes timing diagram. For the SyncControlMode, note that the N-1 image is only present
in the issue 2 camera. The integration time for the N-1 image in general is unknown.
Trigger
AcquisitionFramePeriod
ExposureTime
N
Exposure time
N
Frame output
N+1
N+2
N+1
N+3
N+2
N+3
TimedSync
x
x
x
x