OPERATING AND USER MANUAL Q-12 CoaXPress series
________________________________________________________________________________________________________________
_________________________________________________________________________________________
Adimec
15
Table 4-6: Recommended resistor values
Vext [V]
R1E ext [Ω]
R2E ext [Ω]
3.3
1000
Do not apply
5.0
2000
0
12
4700
470
Figure 4-3: Recommended terminations strobe output and trigger input
4.2.5 Lensmount overview
The Q-12 camera series can be supplied with various optical interfaces. The available interfaces are listed in
Table 4-7. Other interfaces might be possible as well by using converters. Inform at
the possibilities if your interface is not listed in Table 4-7.
Table 4-7: Lensmount overview
Interface
Adjustable
Product name
Product code
M42
No
LENSMOUNT-M42-60
191540
T2
Yes
LENSMOUNT-T2-60
189080
Fn
No
LENSMOUNT-Fn-60
187490
TFLII
Yes
LENSMOUNT-TFLII-60
189590
TFLII
No
LENSMOUNT-TFLII-60
188230