17
metal parts that form the squeegee body to
take off the front rubber.
5.
Clean all the components with water.
To reassemble the squeegee reverse the
operations above.
TROUBLESHOOTING GUIDE
THE SUCTION MOTOR DOES NOT WORK
1.
Check the charge level of the batteries that
is visible when switching on (1) (see under
“BATTERY CHARGING”).
2.
Verify that the suction motor switch (2) is
activated checking that its green signal
lamp is on.
3.
Check the level in the recovery tank (see
under “OVERFILL PROTECTION”) and if
necessary, empty the tank.
If the problem persists, please contact the
authorized technical assistance.
THE BRUSH MOTOR DOES NOT WORK
1.
Check the charge level of the batteries that
is visible when switching on (1) (see under
“BATTERY CHARGING”).
2.
Verify that the brush motor switch (2) is
activated checking that its green signal
lamp is on.
3.
Activate the scrub control levers (3).
If the problem persists, please contact the
authorized technical assistance.
INSUFFICIENT WATER ON THE BRUSH
1.
Check that the solenoid valve switch (1) is
activated verifying that the green signal
lamp is on.
2.
Check the level of the liquid in the solution
tank (see under “SOLUTION TANK”).
3.
Check that the solution flow adjuster (3)
placed in front underneath the solution
tank is sufficiently open.
4.
Press the brush control levers (2).
5.
Check that the solution filter (4) is clean.
If the problem persists, please contact the
authorized technical assistance.