10
SOLUTION TANK
The capacity of the solution tank is indicated in
the technical data.
Open the screw plug (6) situated on top and fill
the solution tank with clean water at a maximum
temperature of 50°C (122°F). Add the liquid
detergent in the percentage recommended by
the manufacturer. To avoid excessive foaming,
which could cause problems to the suction
motor, use the minimum percentage of
detergent. Screw down the plug to close the
tank.
Use always low foam detergent. To avoid
excessive foaming, before starting working
operation, add into the recovery tank a minimum
quantity of anti-foam product.
Never use acid.
FLOOR CLEANING
STARTING OF THE MACHINE
The push buttons on the instrument board are
lighted with an upper green signal LED that
shows the activation of each control.
1.
Switch on the machine pressing the on/off
switch (1).
2.
Check the battery charge level (see under
“BATTERY CHARGING”).
3.
Lower the squeegee by rotating downwards
the handle of the squeegee lifting lever (5)
placed in the centre of the handle bar.
4.
Press the switch for the brush motor (2).
5.
Press the switch for the suction motor (3).
Press the switch for the solenoid valve (4).
The machine is equipped with a solenoid valve,
which activates the solution flow automatically
when the scrub control levers (7) are engaged.
Releasing these levers will stop the flow
automatically.
6.
Activating the levers (7) the brush will start
rotating. The solution flow begins and the
squeegee will start drying the floor.
7.
During the first few meters (feet) check that
the solution flow is appropriate. The flow
adjuster of the solution is already adjusted
at the factory to satisfy the cleaning of
most floors. If it is necessary to adjust the
quantity of solution onto the floor, adjust
the lever of the flow adjuster
(8).