Using Digital I/O on MB-40R XIO Connector
Adept Cobra s350 User’s Guide, Rev. A
43
4.5
Using Digital I/O on MB-40R XIO Connector
The XIO connector on the MB-40R interface panel offers access to digital I/O, 12 inputs
and 8 outputs. These signals can be used by V+ to perform various functions in the
workcell. See
for the XIO signal designations.
• 12 Inputs, signals 1097 to 1108
• 8 Outputs, signals 0097 to 0104
Table 4-6. XIO Signal Designations
Pin
No.
Designation
Signal
Bank
V+
Signal
Number
Pin Locations
1
GND
XIO 26-pin female
connector on
MB-40R Interface
Panel
2
24 VDC
3
Common 1
1
4
Input 1.1
1
1097
5
Input 2.1
1
1098
6
Input 3.1
1
1099
7
Input 4.1
1
1100
8
Input 5.1
1
1101
9
Input 6.1
1
1102
10
GND
11
24 VDC
12
Common 2
2
13
Input 1.2
2
1103
14
Input 2.2
2
1104
15
Input 3.2
2
1105
16
Input 4.2
2
1106
17
Input 5.2
2
1107
18
Input 6.2
2
1108
19
Output 1
0097
20
Output 2
0098
21
Output 3
0099
22
Output 4
0100
23
Output 5
0101
24
Output 6
0102
25
Output 7
0103
26
Output 8
0104
Pin 1
Pin 9
Pin 10
Pin 1
8
Pin 26
Pin 19
Summary of Contents for Cobra s350
Page 1: ...Adept Cobra s350 Robot User s Guide...
Page 2: ......
Page 16: ...Chapter 1 Introduction 16 Adept Cobra s350 User s Guide Rev A...
Page 34: ...Chapter 3 Robot Installation 34 Adept Cobra s350 User s Guide Rev A...
Page 50: ...Chapter 4 MotionBlox 40R 50 Adept Cobra s350 User s Guide Rev A...
Page 62: ...Chapter 5 System Installation 62 Adept Cobra s350 User s Guide Rev A...
Page 66: ...Chapter 6 System Operation 66 Adept Cobra s350 User s Guide Rev A...
Page 84: ...Chapter 8 Maintenance 84 Adept Cobra s350 User s Guide Rev A...
Page 90: ...Chapter 9 Technical Specifications 90 Adept Cobra s350 User s Guide Rev A...
Page 98: ...Chapter 10 Cleanroom Robots 98 Adept Cobra s350 Robot User s Guide Rev A...
Page 102: ...Index 102 Adept Cobra s350 User s Guide Rev A...
Page 103: ......
Page 104: ...3011 Triad Drive Livermore CA 94551 925 245 3400 P N 05624 000 Rev A...