Table 6-9. XIO Breakout Cable Wire Chart
Pin No.
Signal
Designation
Wire Color
Pin Locations
1
GND
White
26-pin male
connector on XIO
Breakout Cable
2
24 VDC
White/Black
3
Common 1
Red
4
Input 1.1
Red/Black
5
Input 2.1
Yellow
6
Input 3.1
Yellow/Black
7
Input 4.1
Green
8
Input 5.1
Green/Black
9
Input 6.1
Blue
10
GND
Blue/White
11
24 VDC
Brown
12
Common 2
Brown/White
13
Input 1.2
Orange
14
Input 2.2
Orange/Black
15
Input 3.2
Gray
16
Input 4.2
Gray/Black
17
Input 5.2
Violet
18
Input 6.2
Violet/White
19
Output 1
Pink
20
Output 2
Pink/Black
21
Output 3
Light Blue
22
Output 4
Light Blue/Black
23
Output 5
Light Green
24
Output 6
Light Green/Black
25
Output 7
White/Red
26
Output 8
White/Blue
Shell
Shield
Pin 9
Pin 1
Pin 18
Pin 10
Pin 19
Pin 26
Summary of Contents for Adept Cobra i600
Page 1: ...Adept Cobra i600 i800 Robot User s Guide ...
Page 2: ......
Page 10: ......
Page 14: ......
Page 34: ......
Page 56: ...Chapter 4 System Installation 56 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 76: ...Chapter 5 Optional Equipment Installation 76 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 104: ...Chapter 6 System Operation 104 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 116: ...Chapter 7 Maintenance 116 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 147: ...Index Adept Cobra i600 i800 Robot User s Guide Rev E 147 ...
Page 148: ......
Page 149: ......
Page 150: ...5960 Inglewood Drive Pleasanton CA 94588 925 245 3400 P N 03589 000 Rev E ...