Internal User Connectors
Adept Cobra i600/i800 Robot User’s Guide, Rev E
63
Internal User Connector Output Specifications
The output specifications in the following table apply to the EOAPWR, OP3/4, and
SOLND internal user connectors.
ESTOP Connector
This 2-pin connector provides a pair of contacts that can be used for a Breakaway E-Stop
function at the end of the arm. See
. The function is disabled by default when the
system is shipped. The user must enable this function using the Configuration Manager
(see below), and connect a normally-closed circuit to pins 1 and 2. When the circuit is
opened, the system will stop in an E-Stop condition. See
.
Table 5-4. Internal User Connector Output Circuit Specifications
Parameter
Value
Power supply voltage range
24 VDC (± 10%), 150 W (6 A)
(21.6 V< V
in
< 26.4 V)
Operational current range, per
channel
I
out
≤
700 mA
Total Current Limitation, all channels
on.
a
a
NOTE
: Total current is the sum of the output current used by output
signals 3001-3004 (SOLND and OP3/4) and any user current drawn
from EOAPWR.
I
total
≤
1.0 A @ 50
°
C ambient
I
total
≤
1.5 A @ 25
°
C ambient
On-state resistance (I
out
= 0.5 A)
Ron
≤
0.32
Ω
@
85
°
C
Output leakage current
I
out
≤
25 µA
Turn-on response time
125 µsec. max., 80 µsec typical
(hardware only)
Turn-off response time
60 µsec. max., 28 µsec typical
(hardware only)
Output voltage at inductive load
turnoff (I
out
= 0.5 A, Load = 1 mH)
(+V - 65)
≤
V
demag
≤
(+V - 45)
DC short circuit current limit
0.7 A
≤
I
LIM
≤
2.5 A
Peak short circuit current
I
ovpk
≤
4 A
Summary of Contents for Adept Cobra i600
Page 1: ...Adept Cobra i600 i800 Robot User s Guide ...
Page 2: ......
Page 10: ......
Page 14: ......
Page 34: ......
Page 56: ...Chapter 4 System Installation 56 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 76: ...Chapter 5 Optional Equipment Installation 76 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 104: ...Chapter 6 System Operation 104 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 116: ...Chapter 7 Maintenance 116 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 147: ...Index Adept Cobra i600 i800 Robot User s Guide Rev E 147 ...
Page 148: ......
Page 149: ......
Page 150: ...5960 Inglewood Drive Pleasanton CA 94588 925 245 3400 P N 03589 000 Rev E ...