Chapter 5 - Optional Equipment Installation
74
Adept Cobra i600/i800 Robot User’s Guide, Rev E
Figure 5-19. Screw Locations for Joint 2 Adjustable Hardstops
Modifying Joint Limit Softstop Locations for Joint 2
After installing the adjustable hardstops, you must modify the softstop locations using the
Configuration Manager utility. See the online help for more details on this utility.
1. Double-click the iCobra object in the Folder pane of the Workspace Explorer.
2. In the object editor, select
Configure > Configuration Manager
.
12 thru holes for M5 x 10 screws,
for installing Joint 2 hardstops, located
30 degrees apart
Joint 2 Left Hardstop Plate,
installed in +81 degree position
Joint 2 Fixed
Hardstop Device
Joint 2
Positive
direction
Joint 2
Negative
direction
Joint 2 Right Hardstop Plate,
installed in -81 degree position
+
_
View of under side of Inner Link, looking up
Summary of Contents for Adept Cobra i600
Page 1: ...Adept Cobra i600 i800 Robot User s Guide ...
Page 2: ......
Page 10: ......
Page 14: ......
Page 34: ......
Page 56: ...Chapter 4 System Installation 56 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 76: ...Chapter 5 Optional Equipment Installation 76 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 104: ...Chapter 6 System Operation 104 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 116: ...Chapter 7 Maintenance 116 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 147: ...Index Adept Cobra i600 i800 Robot User s Guide Rev E 147 ...
Page 148: ......
Page 149: ......
Page 150: ...5960 Inglewood Drive Pleasanton CA 94588 925 245 3400 P N 03589 000 Rev E ...