Page 11
VISTA-40 TWO-PARTITION PROGRAMMING FORM
PARTITION-SPECIFIC FIELDS
(PARTITION #1)
To program these fields,
1. Press
✱
91 to select a partition.
2. Enter a partition-specific field number (ex.
✱
09).
3. Repeat steps 1 & 2 for each partition in the system.
4. To return to the global program fields, enter a global field number.
PARTITION # 1 PROGRAM FIELDS
1st Page Fields
✱
0 9
ENTRY DELAY #1
[02] |
(00-15 times 15 seconds)
✱
1 0
EXIT DELAY #1
[03] |
(00-15 times 15 seconds)
✱
1 1
ENTRY DELAY #2
[06] |
(00-15 times 15 seconds)
✱
1 2
EXIT DELAY #2
[08] |
(00-15 times 15 seconds)
✱
1 3
ALARM SOUNDER DURATION
[04] |
01-15 times 2 minutes. Minimum 4 minutes for UL.
✱
1 6
CONFIRMATION OF ARMING DING
1=enable; 0=disable
✱
2 2
KEYPAD PANIC ENABLES
[0-0-1]
1=enable; 0=disable
95 96 99
✱
2 3
MULTIPLE ALARMS
[1]
1=yes; 0=no
✱
2 9
QUICK ARM
[1]
1=yes; 0=no
✱
3 2
PRIMARY SUBSCRIBER ACCT #
| | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
✱
3 8
PREVENT ZONE XX BYPASS
|
01-64; 00 if all zones (except Fire zones) can be bypassed
✱
3 9
ENABLE OPEN/CLOSE REPORT
FOR INSTALLER CODE
1=enable; 0=disable
✱
8 4
SWINGER SUPPRESSION
[03] |
01-15 alarms; Must be "00" (disabled) for UL.
✱
8 5
ENABLE DIALER REPORTS
FOR PANICS & DURESS
95 96 99 Duress
1=enable; 0=disable
✱
8 7
ENTRY WARNING
[1]
1=continuous; 0=3 beeps
✱
8 8
BURG. ALARM COMM. DELAY
1=16 seconds; 0=no delay
✱
9 0
SECONDARY SUBSCRIBER ACCT #
| | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
2nd Page Fields
1
✱
4 3 PERM. KEYPAD BACKLIGHT
1=enable; 0=disable; When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
1
✱
4 5 EXIT DELAY SOUNDING
1=enable; 0=disable; Produces quick beeping during exit delay if
enabled.
1
✱
4 7 CHIME ON EXT SIREN
1=enable; 0=disable
1
✱
5 2 SEND CANCEL IF ALARM + OFF
1=no restriction; 0=within Bell Timeout period only
1
✱
7 6 ACCESS CONTROL RELAY FOR PARTITION |
Enter relay number that will be pulsed for 2 seconds whenever
code + [0] is pressed. Enter 00-08 00=none
3rd Page Fields
2
✱
1 8 ENABLE GOTO FOR THIS PARTITION
1=enable; 0=disable
2
✱
2 0 ENABLE J7 TRIGGERS by PARTITION
[1]
0=disable for displayed partition; 1=enable for displayed partition