background image

Page 23

+

+

-

N.C.

N.C.

N.O.

2k EOLR

(note 1)

2k EOLR

(note 1)

+

-

+

-

+ -

BELL

SIREN

NO CONNECTION

TRANSFORMER

16.5VAC, 40VA

ADEMCO No.1361

(IN CANADA

USE No. 1361CN)

or 4300 TRANS-  

FORMER IF X-10

 DEVICES 

WILL BE USED

Connect to

24-hr. 120VAC,

60 Hz Outlet

Red

Blk

Grn

Yel

+

+

-

N.C.

N.C.

2k EOLR

(note 1)

2k EOLR

(note 1)

+

+

-

N.C.

+

+

-

N.C.

N.C.

2k EOLR

(note 1,4)

TIP

(BROWN)

RING

(GRAY)

TIP

(GREEN)

RING

(RED)

Handset

Incoming

Phone Line

Telephone connections

using Ademco

direct connect cord 

and RJ31X jack

(CA38A in Canada)

EARTH GROUND
Connect to good earth
ground to maintain im-
munity to transients.
See Instructions for 
proper grounding.

SMOKE

4190
RPM

4278

PIR

Polling loop rating: 64mA  max.
See Installation Instructions for 
maximum number of devices 
supported and maximum
wire run length.

VISTA-40 SUMMARY OF CONNECTIONS

USE UL LISTED 

ENERGY CABLE

FOR ALL 

CONNECTIONS

Zone resistance (Excluding EOLR):
ZONE 1, 8: 100 OHMS MAX.
ALL OTHER ZONES: 300 OHMS MAX.

ZONE 1

ZONE 2 ZONE 3

ZONE 4 ZONE 5

ZONE 6 ZONE 7

ZONE 8 ZONE 9

2-WIRE SMOKE

DETECTOR LOOP

                                        (Also supports NO/NC Burg contacts)

POLLING LOOP

Programmable Response

(Fast/Normal) Loop

LATCHING TYPE GLASS

BREAK DETECTOR LOOP

Data in

Data out

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

RED (

+

)

BLK (

-)

Connect to

12VDC, 4AH 

or 12VDC, 7AH

GEL CELL

BATTERY

CHARGING

VOLTAGE

13.7VDC

See

Installation

Instructions for

required

battery capacity

Replace

every

3 years

NOTE:

WHEN POWERING UP 

THE PANEL, PLUG THE 

TRANSFORMER IN BEFORE

CONNECTING THE BATTERY.

See Installation Instructions

for type & max # of keypads, 

and for max wire run length.

ALARM SOUNDER OUTPUT
10VDC-13.8VDC, 1.7A max.
Note: Combined alarm and auxilary
power output current must be limited
to 750mA for UL installations.

AUXILARY POWER OUTPUT
9.6VDC - 13.8VDC,750mA max.
Note: Include current drawn
by keypads and polling loop
devices when making
auxiliary power calculations.

+

-

NOTES:

1.  Zone 1 may be selected for EOLR supervised 
     or normally closed (no EOLR) operation via cut
     jumper.  (Cut red jumper for normally closed operation. 
     Do not cut for Fire Usage). Zones 2-8 may be selected
     for either operation via program field 

*41.

    

Zone 1 supports 2-wire smoke detectors.
See Installation Instructions for recommended type
and maximum number of detectors supported.

Zone 7 may be used for remote keyswitch arming/disarming. 
See Installation Instructions for wiring instructions.

2.

3.

1  2  3  4  5  6  7  8  9

1. Not Used
2. Ground-
3. Out  1 (Ground Start)
4. Ground-
5. Out  2 (fire)
6. Ground-
7. Out  3 (burg/aud. panic)
8. Ground
9. Out 4 (silent panic/
    duress)

Optional programming:
   Out 1: Open/close or Keypad-like sounding
   Out 2: Armed LED
   Out 4: Ready LED

Ratings for Out 1:
Active: 10VDC-13.8VDC through 4k OHMS
Not  Active: 100 OHMS to ground
Ratings for out 2-4:
Active: 10VDC-13.8VDC through 5k OHMS
Not  Active: 1k OHMS to ground

N.C.

N.O.

N.O.

N.O.

2k EOLR

(note 1,2)

N.O.

N.O.

N.O.

N.C.

N.O.

2k EOLR

(note 1)

2k EOLR

(note 1,3)

N.C.

+

-

J7

GLASS
BREAK

1  2  3  4  5  6  7  8  9

J8

MAKE CONNECTIONS USING

No. 4142TR CABLE

WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED

Fire

Usage

Burg.

Usage

CONNECTION OF THE FIRE ALARM SIGNAL TO
A FIRE ALARM HEADQUARTERS OR A CENTRAL
STATION SHALL BE PERMITTED ONLY WITH THE 
APPROVAL OF THE LOCAL AUTHORITY HAVING
JURISDICTION. THE BURGLAR ALARM SIGNAL 
SHALL NOT BE CONNECTED TO A POLICE
EMERGENCY NUMBER.

1.  I n  2 
2.  Ground
3.  In 3 (4300 sync)
4.  In 4 (4300 sync)
5.  Ground
6.  Out 5 (4300 data)
7.  Out 6 
8.  Ground
9.  Ground

Red Jumper

(note 1)

DOC LOAD No.: 5

J7 Header                           J8 Header

BATTERY

TABS

4192SD
SMOKE

WARNING: TO PREVENT

RISK OF ELECTRICAL

SHOCK, DISCONNECT 
TELCO JACK BEFORE 

SERVICING THIS PANEL.

THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE 
NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARD 72, (NATIONAL 
FIRE PROTECTION ASSOC., BATTERYMARCH PARK, QUINCY, MA. 02269).
PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, OPERATION, 
TESTING, MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE 
IS TO BE PROVIDED WITH THIS EQUIPMENT.

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.

COMPLIES WITH FCC RULES, PART 68
FCC  REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B

THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. 
OPERATION IS SUBJECT TO THE FOLLOWING TWO 
CONDITIONS: (1) THIS DEVICE  MAY NOT CAUSE 
HARMFUL INTERFERENCE, AND (2) THIS DEVICE 
MUST ACCEPT ANY INTERFERENCE RECEIVED, 
INCLUDING INTERFERENCE THAT MAY CAUSE 
UNDESIRED OPERATION.

(Refer to Installation Instructions for information concerning Direct Wire 
Downloading using the 4100SM Serial Module.)

ALL CIRCUITS ARE 
  POWER LIMITED
.

REMOTE KEYPAD

(Addressable keypads)

Zone response time:
ZONES 1-8: 350mSec-500mSec, or 720mSec
ZONE 9: Programmable for
 Fast: 10mSec-15mSec
 Normal: 350mSec-500mSec, or 720mSec
               (default response)

NOTE:     
Zone 5 supports 
AAV Triggering 
(Zone Type 10)
See I.I. for Pro-
gramming and 
Wiring Inform-
ation.

OPTIONAL

4285 VIP

MODULE

   OPTIONAL
4281/5881/5882
RF RECEIVER

SEE INSTRUCTIONS
FOR WIRING DETAILS

         TO

TO: 

 

 6

 

 7   8  9

TO:  6    7    8    9   

  

Blue

Jumper

(note 5)

5.  Cut blue jumper to disable supervision of alarm 
     sounder output. Leave jumper intact to supervise
     output. (See Installation Instructions for Programming 
     and Wiring Instructions). 

Zone 8 supports 2-wire latching type glass break detectors.
See Installation Instructions for recommended type and
maximum number of detectors supported.

4.

Summary of Contents for Ademco VISTA-40

Page 1: ...N7001PRV4 7 98 VISTA 40 2 Partition Security System Programming Guide Single Partition and 2 Partition Programming Forms...

Page 2: ...rocedure with 93 Menu Mode Changing Response type Report Codes Expert Mode Single and 2 Partition Programming Forms plus System Layout Worksheets Two programming forms are provided A Single Partition...

Page 3: ...ICE PROG prompts to program device addresses and characteristics Use the ZONE PROG prompts to program zone information Use the RELAY PROG prompts to program relay output information Use the ALPHA PROG...

Page 4: ...nter 0 9 for each digit or 11 12 13 pause 35 DOWNLOAD PHONE No Enter 0 9 for each digit or 11 12 13 pause 3 6 DOWNLOAD ID No Enter 00 09 A F 10 15 15 15 15 15 15 15 15 15 37 DOWNLOAD COMMAND ENABLES 0...

Page 5: ...Loss AC Restore Test Power Cancel Prog Tamp Second digit of each code applies only to 4 2 or expanded fields 52 53 formats 8 3 FIRST TEST REPORT TIME Day 00 hour 12 min 00 Days 01 07 Hours 00 23 Min...

Page 6: ...er 1 only if AAV unit is used NOTE If enabled zone 5 can no longer be used as a protection zone 1 6 6 SILENCE BELLS DURING AAV 0 alarm sounders continue during AAV sessions 1 alarm sounders silent dur...

Page 7: ...pressing 91 and entering the partition number you wish to program The first partition specific field 09 ENTRY DELAY 1 for that partition automatically appears Refer to the Partition Specific section o...

Page 8: ...System Not Remote Remote Remote Upload Download Shutdwn Shutdwn Used Bypass Disarm Arm Program Program See field 1 53 for Callback disable option 1 enable 0 disable For UL installations all options mu...

Page 9: ...COMM SPLIT REPORT SELECTION 0 no 1 alarms primary others secondary 2 open close test secondary others primary See 51 for comments DIALER CODES Armed Stay Time Set Event Logging 1 4 0 1 4 1 First Digi...

Page 10: ...5 last 6 next to last 7 3rd from last 1 5 1st Sunday in April last in Oct 2 1 7 NUMBER OF CODES PER PARTITION 1 Enter 01 69 Total must be less than or equal to 70 2 Default 69 in part 1 01 in partitio...

Page 11: ...zones can be bypassed 3 9 ENABLE OPEN CLOSE REPORT FOR INSTALLER CODE 1 enable 0 disable 8 4 SWINGER SUPPRESSION 03 01 15 alarms Must be 00 disabled for UL 8 5 ENABLE DIALER REPORTS FOR PANICS DURESS...

Page 12: ...ones can be bypassed 3 9 ENABLE OPEN CLOSE REPORT FOR INSTALLER CODE 1 enable 0 disable 8 4 SWINGER SUPPRESSION 03 01 15 alarms 15 Must be 00 disabled for UL 8 5 ENABLE DIALER REPORTS FOR PANICS DURES...

Page 13: ...smitter serial number polling loop device serial numbers into the system ALPHA PROG 0 no 1 yes For entering alpha descriptors for the following Zone Descriptors Installer s Message Custom Words Partit...

Page 14: ...omplete ZONE RESPONSE TYPE FIELDS Response Types 00 Disabled zone 01 Entry Exit 1 02 Entry Exit 2 03 Perimeter 04 Interior Follower 05 Day Night 06 24 hour Silent Alarm 07 24 hour Audible Alarm 08 24...

Page 15: ...DE 65 ID 66 CODE 67 ID 6 8 33 41 Alarm Rst 34 42 Trouble 35 43 Trble Rst 36 44 Bypass 37 45 Bypss Rst 38 46 39 47 40 48 69 CODE 70 ID 71 CODE 72 ID 7 3 49 57 Alarm Rst 50 58 Trouble 51 59 Trble Rst 52...

Page 16: ...At least one user is assigned per partition regardless of whether or not that partition is actually used A maximum of 70 user codes can be programmed in the system COMMUNICATION OPTIONS BY PARTITION e...

Page 17: ...Type 2 fixed word keypad 3 RF receiver 4 Output Relay module 5 4285 phone module ACCESS CODES USER DEFINITIONS FOR PARTITIONS 1 2 4 digit RF Partition 1 Partition 2 Security Key 2 digit Global Auth Op...

Page 18: ...PM RPM Hard Loop number must be 1 for hardwire and DIP devices Zone Zone tion RF UR BR RPM left lp rght lp Wired Report Zone Information part numbers No Type 1 2 typ 3 typ 4 typ 5 typ 6 typ 7 typ 8 ty...

Page 19: ...PM Hard Loop number must be 1 for hardwire and DIP devices Zone Zone tion RF UR BR RPM left lp rght lp Wired Report Zone Information part numbers No Type 1 2 typ 3 typ 4 typ 5 typ 6 typ 7 typ 8 typ 1...

Page 20: ...yp 8 typ 1 Code Alpha Descriptor 3 words max 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Zone Types 00 zone not used 05 day night burglary 10 interior delay 01 entry exit 1 06 24 hour silent 20 ar...

Page 21: ...JEWELRY 105 KITCHEN 106 LAUNDRY 107 LEFT 108 LEVEL 109 LIBRARY 110 LIGHT 111 LINE 112 LIQUOR 113 LIVING 114 LOADING 115 LOCK 116 LOOP 117 LOW 118 LOWER 119 MACHINE 120 MAGNETIC 121 MAIDS 122 MAIN 123...

Page 22: ...nd restore check in or automatic low battery signals The transmitter may be carried off premises 5801 ENROLL AS UR OR RF LOOP 1 5802 5802CP ENROLL AS BR LOOP 1 5802MN ENROLL AS UR OR RF 5804BD ENROLL...

Page 23: ...ress Optional programming Out 1 Open close or Keypad like sounding Out 2 Armed LED Out 4 Ready LED Ratings for Out 1 Active 10VDC 13 8VDC through 4k OHMS Not Active 100 OHMS to ground Ratings for out...

Page 24: ...N7001PRV4 N7001PRV4 7 98 165 Eileen Way Syosset New York 11791 Copyright 1997 PITTWAY CORPORATION...

Reviews: