Page 10
VISTA-40 TWO-PARTITION PROGRAMMING FORM
3rd Page Programming Fields (press
✱
9 4 )
2
✱
0 0 NUMBER OF PARTITIONS
[1]
Enter 2 for two partition systems.
2
✱
0 1 DAYLIGHT SAVINGS TIME
| |
START/END MONTH
Start
End
00-12; if no daylight savings time, enter 00,00; default=04,10]
2
✱
0 2 DAYLIGHT SAVINGS TIME
|
START/END WEEKEND #
Start | End
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to
last; 7=3rd from last [1,5; 1st Sunday in April, last in Oct.]
2
✱
1 7 NUMBER OF CODES PER PARTITION
1 |
Enter 01-69. Total must be less than or equal to 70.
2 |
[Default=69 in part. 1; 01 in partition 2]
2
✱
1 8 ENABLE GOTO FOR THIS PARTITION
Partition-Specific
2
✱
1 9 USE PARTITION DESCRIPTORS
0=disable;
1=enable
2
✱
2 0 ENABLE J7 TRIGGERS BY PARTITION
Partition-Specific
2
✱
2 1 ENABLE SUPERVISION PULSES FOR LRR
TRIGGER OUTPUTS
| |
Used for supervised connection to 7920SE.
F B S
Enter 0 to disable or 1 to enable the listed outputs.
F= Fire; B= Burglary; S= Silent panic/duress