VISTA-40 SINGLE PARTITION PROGRAMMING FORM
Standard default (
✱
97) values are shown in brackets [ ], otherwise default = 0.
✱
00 INSTALLER CODE
[4140] | | |
Enter 4 digits, 0-9
✱
02 -
✱
05
ASSIGN RESPONSE TYPE FOR ZONES
Skip these fields. Use #93 Menu Mode, Zone
Programming to program response types.
✱
0 9
ENTRY DELAY #1
[02] |
(00-15 times 15 seconds)
✱
1 0
EXIT DELAY #1
[03] |
(00-15 times 15 seconds)
✱
1 1
ENTRY DELAY #2
[06] |
(00-15 times 15 seconds)
✱
1 2
EXIT DELAY #2
[08] |
(00-15 times 15 seconds)
✱
1 3
ALARM SOUNDER DURATION
[04] |
01-15 times 2 minutes . Minimum 4 minutes for UL.
✱
1 4
ZONE 9 FAST/SLOW RESPONSE
1=fast; 0= slow; "0" for UL.
✱
1 5
KEYSWITCH ASSIGNMENT
Enter partition in which keyswitch used, 1-2; 0=disable
✱
1 6
CONFIRMATION OF ARMING DING
1=enable; 0=disable
✱
1 7
AC LOSS KEYPAD SOUNDING
1=yes; 0=no
✱
1 9
RANDOMIZE AC LOSS REPORT
1=randomize 10-40 min.; 0=no
✱
2 0
4285 PHONE MODULE ACCESS CODE | |
Enter 01-09 for 1st digit; 11( for
✴
) or 12 (for #) for
[00]
[11]
2nd digit To disable voice module, enter
1st digit = 00 & 2nd digit = 11
✱
2 1
PREVENT FIRE TIME-OUT
1=no timeout; 0=fire timeout
✱
2 2
KEYPAD PANIC ENABLES
[0-0-1]
1=enable; 0=disable
95 96 99
✱
2 3
MULTIPLE ALARMS
[1]
1=yes; 0=no
✱
2 4
IGNORE EXPANSION ZONE (RF, RPM) TAMPER
1=disable; 0=enable
✱
2 5
LRR BURG.TRIGGER FOR TYPE 8
[1]
1=enable; 0=disable
✱
2 6
INTELLIGENT TEST REPORTING
Set "0" for UL 1=yes, (no report sent if any other report was
recently sent); 0=no
✱
2 7
TEST REPORT INTERVAL
[024] | |
Enter interval in hours, 001-199; 000=no report ; Max. 024 for UL.
✱
28 POWER UP IN PREVIOUS STATE
[1]
1=yes; 0=no; "1" for UL.
✱
2 9
QUICK ARM
[1]
1=yes; 0=no
✱
30 TOUCH-TONE OR ROTARY DIAL
1=TouchTone; 0=rotary
✱
3 1
PABX ACCESS CODE | | | |
00-09; B-F (11-15)
✱
3 2
PRIM. SUBS. ACCT # | | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
✱
33 PRIMARY PHONE NUMBER
Enter 0-9 for each digit, or #11 (
✴
), #12 (#), #13 (pause)
✱
34 SECONDARY PHONE NUMBER
Enter 0-9 for each digit, or #11 (
✴
), #12 (#), #13 (pause)
✱
35 DOWNLOAD PHONE No.
Enter 0-9 for each digit, or #11 (
✴
), #12 (#), #13 (pause)
✱
3 6
DOWNLOAD ID No.
| | | | | | | |
Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15]
✱
37 DOWNLOAD COMMAND ENABLES
0
Dialer
System
Not Remote Remote
Remote Upload
Download
Shutdwn Shutdwn Used
Bypass Disarm
Arm
Program Program
See field 1
✱
53 for Callback disable option; [1=enable]; 0=disable; For UL
installations, all options must be disabled.
✱
3 8
PREVENT ZONE XX BYPASS
|
01-64; 00 if all zones (except Fire zones) can be bypassed
✱
3 9
OPEN/CLOSE REPORT FOR INSTALLER
1=enable; 0=disable
✱
4 0
OPEN/CLOSE REPORTING FOR KEYSWITCH
1=enable;
0=disable
✱
41 NORMALLY CLOSED or EOLR (Zones 2-8)
[1]
1=N.C.loops; 0=EOLR supervision; Must be "0" for UL.
✱
42 DIAL TONE PAUSE
0=5 seconds; 1=11 seconds; 2=30 seconds; Must be "0" for UL.
✱
43 DIAL TONE DETECTION
[1]
1=wait for true dial tone; 0=pause, then dial
✱
44 RING DETECTION COUNT
|
01-14; 15=answering machine; 00=no detection; Do not set to 00 if
voice module is used, or 01 if VIM module is used.
✱
45 PRIMARY FORMAT
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
✱
46 LOW SPEED FORMAT (Primary)
0=Ademco Low Speed; 1=Sescoa/Radionics
✱
47 SECONDARY
FORMAT
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
✱
48 LOW SPEED FORMAT (Sec.)
0=Ademco Low Speed; 1=Sescoa/Radionics
✱
49 CHECKSUM VERIFICATION
1=yes; 0=no
Prim Scndry
✱
50 SESCOA/RADIONICS
SELECT
1=Sescoa; 0=Radionics
✱
51 DUAL REPORTING
1=yes; 0=no; If used with Spilt Reporting "1" option (1
✱
34), alarms
go to both primary & secondary numbers, while all other reports go
to secondary only. If used with Split Reporting "2" option,
open/close and test messages go to both lines, while all other
reports go to primary.
✱
52 STANDARD/EXPANDED REPORT FOR PRIMARY
Alarm
Rstr
Bypass
Trbl
Opn/Cls Low Bat
0=standard; 1=expanded; Note: Expanded overrides 4+2 format.
✱
53 STANDARD/EXPANDED REPORT FOR SECONDARY
Alarm
Rstr
Bypass
Trbl
Opn/Cls Low Bat
0=Standard; 1=Expanded; Note: Expanded Overrides 4+2 Format.