CHANGING ZONE RESPONSE TYPE AND
REPORT CODE DATA FIELDS (Expert Mode)
•
Because the VISTA-40 supports various types of input devices (such as button type transmitters, serial
number polling loop devices, etc.), zone characteristics, including zone response types and report codes,
must be initially programmed using #93 Menu Mode. However, once a zone has been programmed,
changes in response type or report code can be made using the respective data fields. This section lists
these fields.
•
Zone Response Type and Report Code fields will automatically appear during normal programming, but
must be skipped if the zone has not been previously programmed. These fields include:
✱
02 -
✱
05 and 1
✱
01 - 1
✱
09 ASSIGN RESPONSE TYPES
✱
54 -
✱
78 REPORT CODES
To program these fields:
1. Enter Program Mode (enter installer code + [8] + [0] + [0]).
2. Press [
✱
] followed by the data field you wish to program.
3. Refer to the following list of fields when programming Zone Response Types and/or Report Codes.
4. Press
✱
99 to exit program mode when programming is complete.
ZONE RESPONSE TYPE FIELDS
Response Types:
00 = Disabled zone
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
04 = Interior Follower
05 = Day/Night
06 = 24 hour Silent Alarm
07 = 24 hour Audible Alarm
08 = 24 hour Auxiliary
09 = Fire
10 = Interior, Delay
20 = Arm stay
21 = Arm away
22 = Disarm
23= No alarm response
N o t e s :
Use of 1 or 2 RF RCVRs requires enabling their
respective faults (88-91) as troubles (type 5).
Enter 00 if no annunciation is desired.
88 & 90 = RCVR not receiving transmitter signals.
89 & 91 = RCVR not responding, bad conn. to panel.
87 = voice module supervision (type 05)
98 = Bell supervision (type 05)
✱
02 -
✱
05 ASSIGN RESPONSE TYPE FOR ZONES 1-27
(Enter 00-10; see Response Types below) see fields 1
✱
01-1
✱
09 to program
response types for zones 28-87.
✱
0 2
✱
0 3
✱
0 4
✱
0 5
1 |
[9]
9 |
17 |
25 |
2 |
[3]
10 |
18 |
26 |
3 |
[3]
11 |
19 |
27 |
4 |
[3]
12 |
20 |
0 | 0
5 |
[3]
13 |
21 |
97 |
poll loop short
6 |
[3]
14 |
22 |
95 |
(1+
✱
or A panic)
7 |
[3]
15 |
23 |
96 |
(3+ # or C panic)
8 |
[3]
16 |
24 |
99 |
(
✱
+ # or B panic)
ASSIGN RESPONSE TYPE FOR ZONES
(Enter 00-10; see Response Types below)
1
✱
0 1
1
✱
0 2
1
✱
0 3
1
✱
0 4
1
✱
0 5
28 |
33 |
41 |
49 |
57 |
29 |
34 |
42 |
50 |
58 |
30 |
35 |
43 |
51 |
59 |
31 |
36 |
44 |
52 |
60 |
32 |
37 |
45 |
53 |
61 |
38 |
46 |
54 |
62 |
39 |
47 |
55 |
63 |
40 |
48 |
56 |
64 |
1
✱
0 9
87 | Voice Module
88 | 2nd RCVR
89 | 2nd RCVR
90 | 1st RCVR
91 | 1st RCVR
0 | 0
98 | Bell Supervision