2-1
S E C T I O N 2
Mounting and Wiring
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
Mounting the 4286 VIP Module
♦
Wiring Connections
♦
Speaker Connections and Volume Control
♦
Caller ID Units
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Mounting the 4286 VIP Module (All Controls)
•
Mount the 4286 VIP Module in the control cabinet if space is available, or
on the side of the cabinet or adjacent to it. Pry off the 4286’s cover prior
to wiring.
•
If mounted inside the cabinet with the control, use double-sided adhesive
tape to attach the Module to the interior surface of the cabinet, or hang
on two screws. Do not mount on the cabinet door or attempt to at-
tach it to the PC board. The 4286's cover can be left off if the Module
is mounted within the cabinet.
•
To mount the 4286 outside the cabinet, use the screw holes at the rear of
the Module, which can be mounted horizontally or vertically (double-
sided adhesive tape may be used in place of screws, if preferred). Wires
can be brought out from the side or back (use the round breakout on the
back). When the 4286’s wiring is completed (as shown below), replace the
Module's cover (with label affixed, as indicated next).
•
Affix the supplied connections label to the inside of the 4286's cover if the
cover is to be used. Otherwise, affix the label to the inside of the control
cabinet's door.