4286 VIP Module Installation and Setup Guide
3-4
2.
Enter the same address in this field
In a system that uses non-addressable keypads:
Set this field to 31 to enable phone panics.
Field 02: Control Panel Type
1 = Vista-10, Vista-10SE, Via-30P, Via-30PSE, and 4140XMP (with voice up-
grade EPROM)
2 = Vista-20, Vista-20HW, Vista-20SE, and Vista-20HWSE
4 = Vista-40, Vista-50P, Vista-100, Vista-120, and Vista-128FB
Field numbers 03 to 15 refer to 4500 Thermostat settings and shall be pro-
grammed using the thermostat’s Installation Instructions manual. Should you
make an entry error, the defaults are listed below for quick reference.
Field
•
Description
Default Entry
•
Default Description
03
Unit of temperature
•
0
Temperature in degrees F
04
Thermostat #1 enable
•
00
Thermostat #1 disabled
05
Thermostat #1 swing
•
1,4
0.0 deg F, -1.0 deg F
06
Announce thermostat #1 temp
•
0
Do not announce
07
Thermostat #1 voice descriptor #1
•
000
No announcement
08
Thermostat #1 voice descriptor #2
•
000
No announcement
09
Thermostat #1 voice descriptor #3
•
000
No announcement
10
Thermostat #2 enable
•
00
Thermostat #2 disabled
11
Thermostat #2 swing
•
1,4
0.0 deg F, -1.0 deg F
12
Announce thermostat #2 temp
•
0
Do not announce
13
Thermostat #2 voice descriptor #1
•
000
No announcement
14
Thermostat #2 voice descriptor #2
•
000
No announcement
15
Thermostat #2 voice descriptor #3
•
000
No announcement
Programming Zone Descriptors
This Section Applies to Systems Using Alpha or Fixed-Word Keypads..
Zone descriptors MUST be programmed into the control panel, even if the
system uses only fixed-word keypads. If this is not done, the 4286 VIP Mod-
ule will annunciate zone numbers only, with no descriptors. In an existing