Configuring with an ASCII Terminal
Campus-REX RS Interface Card User Manual
5-25
6
Click
Comm
,
Comm Port
, then select the COM port to which the
Campus-RS unit is connected.
7
Click
Comm
,
Baud Rate
,
9600
.
8
Click
Protocol
,
DNL Mode
.
9
In the
DNL Mode Options
box, set the DNL Rate to
Standard
.
10
In the
DNL Mode Options
box, set the Destination to
Local
.
11
Select the directory and file you want to copy to the Campus-RS unit.
The path and file name display in the
Firmware File to Upload
box.
12
Click
Start Upload
.
Within 20 seconds, a status bar displays to indicate upload progress.
When the upload is complete, the unit resets and terminates Download
Mode. If the Test LED remains lit, indicating that the unit is still in
Download Mode, the file was not copied successfully. Repeat the
procedure until the copy is successful.
13
Follow the steps in
“Returning Configuration Options to Default Values”
to restore the Campus-RS unit configuration options to their
default values.