3.5 Wiring
To connect the wiring for the OBSL-L perform the following procedure:
Feed two 18 AWG wires for power input and one 18AWG ground wire through on-site conduit. Make connection to power
source through the terminal blocks used with the OBSL-L Single L-810(L).
All wiring to be in accordance with site plans or local electrical codes.
Wire specific fixtures as follows:
Figure 1: Single Wiring Connections
95-277 VAC POWERED
X3 = 1
GREEN
BLUE
BROWN
44A7734 HARNESS IS USED ONLY ON 120 VAC
UNITS WHERE AN ARCTIC KIT IS SPECIFIED
12 VDC OR 24-48 VDC POWERED
X3 = 2 OR 3
44A7668/XXXXX
OBSL W-IR OPTIC ASSEMBLY
Not used for:
44A7567
HARNESS ASSY, POWER SUPPLY TO LED DRIVER
44A7672/1
SBOL W-IR Cordset Assembly
44A7667/XXXX
POWER SUPPLY ASSEMBLY SBOL W-IR1
96A0476, Rev. F, 2019/12/12
11