3. Lift the power supply assembly out of the fixture housing.
•
Locate and disconnect the incoming power and the 44A7734 arctic kit harness cables (if used). See
.
•
The cordset wires are shown in
4. Re-connect the power leads to the new power supply assembly and reconnect the LED leads to the PCB. If present,
reconnect the 44A7734 artic kit harness.
5. Insert the PCB assembly back into the housing and secure with the M4 Pan-head Phillips Screws. Torque to 12-15 in-lb (1.4
- 1.7 N·m).
6. Reinstall 44A7668 optic assembly and reconnect the leads per
Note
Insure that the two LED leads do not become pinched when placing the LED assembly back into the housing. Latch
the Glassware Assembly back onto the housing.
7. Reinstall the repaired fixture back at the site location.
96A0476, Rev. F, 2019/12/12
17
Copyright
©
ADB Safegate, All Rights Reserved