Tools:
•
Screwdriver, Torx T20 and T25
Install
1. Install the cooling block on the body. See §
Part replacement - cooling block
2. Install the optical kit on the cooling block. See §
Part replacement - optical kit
3. Install the optical cover. See §
Part replacement - optical cover
4.4 Fixture operation test
Tools
•
FAA or IEC series isolation transformer, powered from a FAA or IEC constant current regulator
1. Connect the fixture directly to the transformer. Do not use a remote communication unit between the fixture and the
transformer.
2. Set the step of the constant current generator to 6.6 A.
3. Check if the light works properly for 10 s.
4. Turn OFF the constant current generator.
5. If the fixture did not work or has switched off before the end of the test time, see §
AM.03.120e, Rev. 3.4, 2019/03/29