CAUTION
Make sure that:
•
The fixture is powered from a 6.6 A series circuit.
•
The series circuit is powered by a Constant Current Regulator that complies with IEC 61822 or FAA AC 5345-10
(latest revision).
•
The transformer is series isolation transformer that complies with IEC 61823 or FAA AC 5345-47 (latest revision);
the power of the series transformer shall not exceed 200 W. This does not apply for IQ or IQ 2A installations where
larger transformers can or should be used. Please contact your sales representative for more information.
•
The mounting support is correctly earthed. Failure to do so will void the warranty for all damages that occur as a
result of voltage surges.
Note
See the Instruction Manual of the mounting support for instructions on how to earth the mounting support.
Parts:
•
Complete fixture
Tools:
•
Open spanners
•
Alignment tool
3.3.1 Intended Use
CAUTION
Use this equipment as intended by the manufacturer
This equipment is designed to perform a specific function, do not use this equipment for other purposes
• Using this equipment in ways other than described in this manual may result in personal injury, death
or property and equipment damage. Use this equipment only as described in this manual.
Failure to follow this instruction can result in serious injury or equipment damage
3.3.2 Preparation
1. Make sure that the fixture is completely assembled.
2. Make sure that the fixture is operationally tested.
EREL / ERES
Install or replace the fixture
12
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for EREL
Page 1: ...EREL ERES User Manual AM 03 120e Rev 3 4 2019 03 29 ...
Page 2: ......
Page 10: ...EREL ERES Safety 4 Copyright ADB Safegate All Rights Reserved ...
Page 42: ...EREL ERES Maintenance 36 Copyright ADB Safegate All Rights Reserved ...
Page 49: ...AM 03 120e Rev 3 4 2019 03 29 43 Copyright ADB Safegate All Rights Reserved ...
Page 50: ......