Last Step
In the View menu, select
Refresh
. All iSCSI Storage Appliances, iSCSI targets, and
mirrored volumes should appear online, connected, and in normal status. The
recovery of each iSCSI Storage Host is complete.
Recovery on Systems Running Windows XP, Linux, or VMware
This section provides a general overview of the steps required to reconnect to each
system in your IPSAN that’s running an OS besides Windows 2003 or Windows
Vista. For specific instructions, refer to the documentation provided with your
iSCSI initiators.
1
Remove all iSCSI target sessions from the iSCSI initiator.
2
Remove all iSCSI Storage Appliance data ports from the iSCSI initiator.
3
Add the IP address(es) of the data port(s) on your iSCSI Storage Appliance.
4
Your iSCSI initiator may automatically discover the iSCSI targets on your iSCSI
Storage Appliance. If not, manually add the iSCSI targets to the iSCSI initiator.
The recovery of each system is complete.
Recovering from a Flash Drive Failure in a Mirrored Environment
Follow the instructions in this section if a flash drive fails in an iSCSI Storage
Appliance that is part of a mirror.
1
Complete these tasks, as described in previous sections:
a
Shut down the iSCSI Storage Appliance (see page 155).
b
Replace the flash drive (see page 155).
c
Power on and configure the iSCSI Storage Appliance (see page 36).
Note
When configuring your iSCSI Storage Appliance, use settings that are
identical
to the previous configuration, if possible.
2
In the CLI, ensure you are logged on as Administrator. (If you are, a ‘#’ appears at
the prompt.)
Summary of Contents for 5325302053 - Snap Server 720i NAS
Page 1: ...Snap Server 700i Series User s Guide for Adaptec OnTarget Powered Snap Servers ...
Page 6: ......
Page 12: ...6 Snap Server 700i User s Guide ...
Page 18: ......
Page 32: ......
Page 88: ......
Page 96: ......
Page 120: ......
Page 168: ......
Page 184: ......
Page 194: ......
Page 214: ......
Page 218: ......