background image

 

© Adam Equipment Company 2008 

 

 
 

 

 
ADAM EQUIPMENT

 is an ISO 9001:2000 certified global company with more than 35 

years experience in the production and sale of electronic weighing equipment.   
 
Adam products are predominantly designed for the Laboratory, Educational, Medical, 
retail and Industrial Segments. The product range can be described as follows: 
 

-Analytical and Precision Balances 
-Compact and Portable Balances 
-High Capacity Balances 
-Moisture analysers / balances 
-Mechanical Scales   
-Counting Scales 
-Digital Weighing/Check-weighing Scales 
-High performance Platform Scales   
-Crane scales 
-Medical Scales 
-Retail Scales for Price computing 

 

For a complete listing of all Adam products visit our website at 

www.adamequipment.com

 

 

 

 
 

 
 
 
 

 

 

© Copyright by Adam Equipment Co. Ltd.    All rights reserved.    No part of this publication 

may be reprinted or translated in any form or by any means without the prior permission of 

Adam Equipment. 

 

Adam Equipment reserves the right to make changes to the technology, features, 

specifications and design of the equipment without notice. 

 

All information contained within this publication is to the best of our knowledge timely, 

complete and accurate when issued.    However, we are not responsible for 

misinterpretations which may result from the reading of this material. 

 

The latest version of this publication can be found on our Website. 

 

www.adamequipment.com 

 

 

 

 

Summary of Contents for AE-202

Page 1: ...Adam Equipment Company 2008 Adam Equipment AELP Pallet Beams AE 202 Indicators P N 9359 Rev A1 August 2008...

Page 2: ...Adam Equipment Company 2008...

Page 3: ...N KILOGRAM TO POUND 11 5 9 HOLD FUNCTION ANIMAL WEIGHING 11 5 10 COUNT OPERATION 11 5 11 HIGH RESOLUTION DISPLAY 12 6 0 BATTERY OPERATION 13 6 1 BATTERY CAPACITY 13 6 2 BATTERY CHARGE PROMPT 13 6 3 OV...

Page 4: ...Adam Equipment Company 2008 2...

Page 5: ...the following standard features Lightweight for ease of handling Supplied complete with the AE 202 Indicator in plastic housing Precision load cells for accurate weighing results every time Handles fo...

Page 6: ...cumulation facility Selectable automatic power off Bi directional RS 232 Interface Operation from internal rechargeable battery or main power Lockable keyboard calibration and configuration for securi...

Page 7: ...ad acid battery charged by internal power supply Interface Bi directional RS 232 Interface RS 232 Connector 9 Pin d sub miniature socket Display LED Calibration Lockable keyboard calibration Housing P...

Page 8: ...ove the Indicator and the power supply adapter packed separately Place it on a level and firm floor Position the beams side by side Plug in the Indicator into the socket provided at the back of the pa...

Page 9: ...ight Zero The scale is at zero Lb Show pounds as unit of weight The keys perform the following functions Zero Zero the display set the zero point or enter a tare value Tare Tare the balance x10 Inc Sh...

Page 10: ...ry The value xx will vary from a low value of about 10 to a maximum of 99 To switch off the power press the On Off key again It may be necessary to hold the key a few seconds until display shows oFF W...

Page 11: ...o select and the Kg lb Set key to enter your selection and return to normal weighing Note In automatic accumulation state the Auto indicator will be on 5 5 MANUAL MEMORY ACCUMULATION If the accumulati...

Page 12: ...will show n 0 followed by zero weight If you wish to clear the memory press the Kg lb Set to view totals then Zero when the totals are being displayed key 5 7 ACCUMULATION VALUE DISPLAY PRINT AND CLEA...

Page 13: ...the weight is increased or returns to zero The higher the value the stronger the filter will be for animal weighing applications To un Hold the display to continue weighing or return to zero you may...

Page 14: ...e Kg lb Set is pressed directly the value shown will be based on the sample value set previously Press the On off key to enter weighing mode and the Count indicator will be switched off 5 11 HIGH RESO...

Page 15: ...immediately 6 3 OVER DISCHARGE PROTECT When battery capacity is less than 10 the indicator will be switched off automatically to avoid battery over discharge 6 4 POWER SAVING MODE Auto power saving mo...

Page 16: ...to the scale Wait for the stable indicator and press the Kg lb Set key After the calibration is complete the display will return to the normal weighing mode Note 1 If the zero point is correct and jus...

Page 17: ...yed in the format F AbCdE The related functions are listed below Press Acc The first digit will start flashing Press the x10 Inc key to change the options 0 or 1 Press Acc to move to the next digit On...

Page 18: ...TION PARAMETERS These set of parameters allow you to set the values for functions that control communicating with a PC or a printer via the RS 232 interface 8 2 1 COMMUNICATION ADDRESS The value as se...

Page 19: ...to scroll through the other options 1200 2400 4800 9600 Select the desired setting by pressing Kg lb Set and move to the last parameter for viewing the A D Count 8 2 3 A D COUNT Press Acc to show the...

Page 20: ...F Send Total of accumulator C CR LF Clear Totals of accumulator Z CR LF Zero Tare the scale OUTPUT FORMATS n item number w the weight u units Continuous output 14 ASCII Characters leading zeros are sp...

Page 21: ...lf lf lf lf I e cr lf n _ _ _ 6 cr lf t o t a l _ _ 6 2 5 K G cr lf lf lf lf lf 10 0 LOAD CELL CONNECTION Load cell supply voltage 5 VDC Pin 1 2 E Load cell excitation positive Pin 4 5 E Load cell exc...

Page 22: ...dead load is applied Err 5 Range calibration has failed Check that load cell is wired correctly and is the correct size and output for scale Ensure that correct mass was loaded Err 6 Weighing value ca...

Page 23: ...er methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and kee...

Page 24: ...Adam Equipment Company 2008 22...

Page 25: ...ease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warra...

Page 26: ...Adam Equipment Company 2008 24...

Page 27: ...n a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with t...

Page 28: ...edical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of...

Reviews: