background image

 

©Adam Equipment Company 2008 

23 

 
 
 
 
 
 

WARRANTY INFORMATION 

 

 

Adam Equipment offers Limited Warranty (Parts and Labour) for the components 

failed due to defects in materials or workmanship.    Warranty starts from the date 

of delivery. 

 

During the warranty period, should any repairs be necessary, the purchaser must 

inform its supplier or Adam Equipment Company. The company or its authorised 

Technician reserves the right to repair or replace the components at the 

purchaser’s site or any of its workshops depending on the severity of the problems 

at no additional cost. However, any freight involved in sending the faulty units or 

parts to the service centre should be borne by the purchaser. 

 

The warranty will cease to operate if the equipment is not returned in the original 

packaging and with correct documentation for a claim to be processed. All claims 

are at the sole discretion of Adam Equipment. 

 

This warranty does not cover equipment where defects or poor performance is due 

to misuse, accidental damage, exposure to radioactive or corrosive materials, 

negligence, faulty installation, unauthorised modifications or attempted repair or 

failure to observe the requirements and recommendations as given in this   

User Manual. 

 

Repairs carried out under the warranty does not extend the warranty period. 

Components removed during the warranty repairs become the company property. 

 

The statutory right of the purchaser is not affected by this warranty. The terms of 

this warranty is governed by the UK law. For complete details on Warranty 

Information, see the terms and conditions of sale available on our web-site. 

 
 
 
 
 
 
 
 
 
 
 

 

 
 

 

 

Summary of Contents for AE-202

Page 1: ...Adam Equipment Company 2008 Adam Equipment AELP Pallet Beams AE 202 Indicators P N 9359 Rev A1 August 2008...

Page 2: ...Adam Equipment Company 2008...

Page 3: ...N KILOGRAM TO POUND 11 5 9 HOLD FUNCTION ANIMAL WEIGHING 11 5 10 COUNT OPERATION 11 5 11 HIGH RESOLUTION DISPLAY 12 6 0 BATTERY OPERATION 13 6 1 BATTERY CAPACITY 13 6 2 BATTERY CHARGE PROMPT 13 6 3 OV...

Page 4: ...Adam Equipment Company 2008 2...

Page 5: ...the following standard features Lightweight for ease of handling Supplied complete with the AE 202 Indicator in plastic housing Precision load cells for accurate weighing results every time Handles fo...

Page 6: ...cumulation facility Selectable automatic power off Bi directional RS 232 Interface Operation from internal rechargeable battery or main power Lockable keyboard calibration and configuration for securi...

Page 7: ...ad acid battery charged by internal power supply Interface Bi directional RS 232 Interface RS 232 Connector 9 Pin d sub miniature socket Display LED Calibration Lockable keyboard calibration Housing P...

Page 8: ...ove the Indicator and the power supply adapter packed separately Place it on a level and firm floor Position the beams side by side Plug in the Indicator into the socket provided at the back of the pa...

Page 9: ...ight Zero The scale is at zero Lb Show pounds as unit of weight The keys perform the following functions Zero Zero the display set the zero point or enter a tare value Tare Tare the balance x10 Inc Sh...

Page 10: ...ry The value xx will vary from a low value of about 10 to a maximum of 99 To switch off the power press the On Off key again It may be necessary to hold the key a few seconds until display shows oFF W...

Page 11: ...o select and the Kg lb Set key to enter your selection and return to normal weighing Note In automatic accumulation state the Auto indicator will be on 5 5 MANUAL MEMORY ACCUMULATION If the accumulati...

Page 12: ...will show n 0 followed by zero weight If you wish to clear the memory press the Kg lb Set to view totals then Zero when the totals are being displayed key 5 7 ACCUMULATION VALUE DISPLAY PRINT AND CLEA...

Page 13: ...the weight is increased or returns to zero The higher the value the stronger the filter will be for animal weighing applications To un Hold the display to continue weighing or return to zero you may...

Page 14: ...e Kg lb Set is pressed directly the value shown will be based on the sample value set previously Press the On off key to enter weighing mode and the Count indicator will be switched off 5 11 HIGH RESO...

Page 15: ...immediately 6 3 OVER DISCHARGE PROTECT When battery capacity is less than 10 the indicator will be switched off automatically to avoid battery over discharge 6 4 POWER SAVING MODE Auto power saving mo...

Page 16: ...to the scale Wait for the stable indicator and press the Kg lb Set key After the calibration is complete the display will return to the normal weighing mode Note 1 If the zero point is correct and jus...

Page 17: ...yed in the format F AbCdE The related functions are listed below Press Acc The first digit will start flashing Press the x10 Inc key to change the options 0 or 1 Press Acc to move to the next digit On...

Page 18: ...TION PARAMETERS These set of parameters allow you to set the values for functions that control communicating with a PC or a printer via the RS 232 interface 8 2 1 COMMUNICATION ADDRESS The value as se...

Page 19: ...to scroll through the other options 1200 2400 4800 9600 Select the desired setting by pressing Kg lb Set and move to the last parameter for viewing the A D Count 8 2 3 A D COUNT Press Acc to show the...

Page 20: ...F Send Total of accumulator C CR LF Clear Totals of accumulator Z CR LF Zero Tare the scale OUTPUT FORMATS n item number w the weight u units Continuous output 14 ASCII Characters leading zeros are sp...

Page 21: ...lf lf lf lf I e cr lf n _ _ _ 6 cr lf t o t a l _ _ 6 2 5 K G cr lf lf lf lf lf 10 0 LOAD CELL CONNECTION Load cell supply voltage 5 VDC Pin 1 2 E Load cell excitation positive Pin 4 5 E Load cell exc...

Page 22: ...dead load is applied Err 5 Range calibration has failed Check that load cell is wired correctly and is the correct size and output for scale Ensure that correct mass was loaded Err 6 Weighing value ca...

Page 23: ...er methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and kee...

Page 24: ...Adam Equipment Company 2008 22...

Page 25: ...ease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warra...

Page 26: ...Adam Equipment Company 2008 24...

Page 27: ...n a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with t...

Page 28: ...edical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of...

Reviews: