58
P7– 6 & 7. Gap & Peel off Threshold
It is recommended that this option is designed for user who was using
that before
To set Gap & Peel off Threshold:
1. Follow steps 1 to 3 of entering Main Menu.
2. Press
7
6
or
7
.
3. Enter the Gap Threshold value & Peel off Threshold you wish to
assign the scale to. This number must be from 1 to 255. As you type
the number, you will see it in the Total Price Display. The default
setting values are 150.
4. Press
ESC
SET
to save the setting and return to the
Initial State.
P7- 8. Label Format Setting
The LFS (Label Format Setting) tells the scale what label you are using
and how you want it to print on that label. The LFS is a number from 1
to 999; however, the scale will only accept those values listed in the
Label Format Library, Appendix A. The NETS is compatible with many
competitor label formats and labels: please check the appendix.
Common LFS Numbers: 43 & .
To set the Label Format:
1. Follow steps 1 to 3 of entering Main Menu.
2. Press
7
8
.
3. Select the LFS number from the Label Format Library and press
; as you type the number it will appear in the Total Price Display.
The default value is 43 and is the format for the labels that come with a
new scale.
4. Press
ESC
SET
.
5. You are back in the Initial State.