20
DoorLIFT DL
-
6
Remote door system
8.5 Optional functions
8
-
lead wire harness
Wire
Item
1
Up/down input
2
Up input
3
Down input
4
Signal block (ignition lockout)
5
+ 12V output (max 250 mA)
6
Door ajar output (ground)
7
Cargo light output (ground)
Yellow/green
Ground (max 250 mA)
Connect auxiliary devices to the DoorLIFT control box through the 8
-
lead auxiliary harness using the wire chart below as a guide. The
pig
-
tailed end of the harness has numbers.
The 8
-
pin male receptacle on the box comes equipped with a plug
to protect the connector from water and dirt if the harness is not
used. This plug is removed if the harness is utilized.
WARNING:
Protect unused harness leads against water, debris, dust and possible short
-
circuits
Push in until you hear it
“
click
”
Installation guide