![Active Olivator Owner'S Operation And Maintenance Manual Download Page 25](http://html1.mh-extra.com/html/active/olivator/olivator_owners-operation-and-maintenance-manual_2843585025.webp)
25
ACTIVE S.r.l. Via Delmoncello, 12 - 26037 SAN GIOVANNI IN CROCE - CR -
Tel. 0375 – 91742
www.active-srl.com
email :
Fix the new tine in the support Y and then in the housing P, pushing it down eventually using a hammer.
Screw the locking nut up to the limit.
8.
ORDINARY MAINTENANCE
Codes E1200L- E1200XL E4800L- E4800XL E4800 BPL- E4800 BPXL Rif. Fig. F
MAINTENCANCE
Maintenance has to be carried on by qualified personnel, following the instructions of this manual and
using only original spare parts. User has to follow all the applicable safety laws, using as necessary the
right protective equipment.
IMPORTANT : Every 50 working hours, the internal mechanisms of the head have to be
lubricated with grease for high temperatures. The points have to be lubricated according to
the picture F.
Follow the instructions in fig. F for the grease input.
Rotate the head in order to have access to the rear part (fig. F.1) and identify the two holes V. Unscrew
the two screws W, as indicated in fig. F.2. Using one needleless syringe, as indicated in fig. F.3, put the
grease inside using the holes V. Reassemble the screws and tighten them down.
LONG TERM MAINTENANCE
In case of long lasting inactivity periods, the machine has to be carefully cleaned and then protected
from dust and humidity in a dry place clear from direct sun and freeze. The battery shall not be
connected with the machine as is it is not in use. It shall be stored with full charge and re-charged every
three months.
CHECKS AND ANOMALIES
COMPONENT
ACTION
FREQUENCY
Clamps and connectors
Check the integrity and efficiency of
the contacts
Every day
Power cable
Check that the cable is not twisted
Every day
Tines
Check the integrity and locking
Every day
ANOMALIES (
E1200L- E1200XL
)
CAUSE
SOLUTION
By pressing the
start button the
motor does not
turn on or turns
on slowly.
Damaged clamps or connectors
Replace
Damaged cables
Replace
Damaged motor
Replace
Empty battery
Replace or recharge
Low battery
Recharge
Other
Contact the service
point
ANOMALIES (
E4800L-E4800XL E4800BPL-E4800 BPXL
)
CAUSE
SOLUTION
By pressing the
start button the
motor does not
turn on.
All the LEDs of the power supply are off.
Damaged clamps or connectors
Replace
Interrupted fuse
Replace
Damaged electronic power supply
Replace
LEDs are regularly ON
Damaged cables
Replace
LEDs are regularly ON
Damaged motor
Replace
ALARM red light ON
Empty battery
Replace or recharge
ALARM red light ON (single impulse)
Low battery
Recharge
ALARM red light ON (multiple impulses)
Anomaly
Contact the service
point