ACTpro 3000 Operating Instructions
Firmware Version 1.24
22
Change PIN
The
Change PIN
function allows a different PIN to be configured for the installer. The user will
be prompted to enter a new six-digit code (it will not be displayed). The PIN must then be re-
entered for verification. The PIN will be accepted as long as it does not conflict with any existing
code (or duress code).
Factory Default
This function returns all settings to the factory default. All user names, timezones, card enables,
log information and Operator and Installer Code and all other settings are defaulted.
All
information previously programmed will be lost, so use this function with care.
In situations where the Installer Code is unknown the Controller may be defaulted as follows.
Holding down the
✘
key while powering up the Controller, when requested for a Site Code enter
the ACT default Site Code 10-2770-09, When asked to default controller hit the
✔
key to default.
It is always a good idea to factory default a new controller prior to initial configuration, or if the
controller software has been changed or upgraded.
After entering this Menu a door must be selected where the test is performed and then the “Swipe
Card” is displayed on the second line. The card should then be presented to the reader attached to
the selected door.
Once the card has been presented, the display will update. The top line shows the number of bits
of data followed by the type of data (C for “Clock and Data” or W for “Wiegand”), followed by
the number of digits on the card, followed by a slash "/", followed by the last 10 digits read from
the card.
If the data the on the card matches the ACT site code format then second line will display the Card
data in the ACT Site, otherwise it will display data as read from the card.
Example: 32-bit Wiegand Card Data:
Last Reset
This menu may be used by ACT technical support.
32W10/0915265139
0915265139