ACTpro 3000 Operating Instructions
Firmware Version 1.24
18
•
The
Exit Denied
alarm activates the AUX relay for the programmed duration whenever an
invalid card is presented to an exit reader.
•
The
Relay Follow
alarm activates the AUX relay whenever the Main relay is active.
•
The
Arm Intruder
option allows the AUX relay to be use to ARM/DISARM external alarm
panels. See end of manual for more information,
TIMERS
The door timers menu allows the installer to program the time delays for the relay, AUX output,
open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer may be programmed
with a duration from 1 to 999 seconds. The relay time may be programmed to 0 seconds, which
will operate the relay for a quarter of a second approximately. This can be used for turnstile
applications. Door Stations will support a maximum duration of 127 seconds.
Timed Actions
This Menu allows the user to set up a number of actions that will occur at requested times. The
time that a particular action should occur is set up in a timezone and then assigned to that action.
When the timezone is in force, then the assigned action occurs for that duration.
Action
What Happens
Unlock Door
For the duration of the assigned timezone, the door remains
unlocked
. The
Green LED on the Reader will Flash
Lock Door
For the duration of the assigned timezone, the door remains
locked
. The Red
LED on the Reader will Flash.
PIN Required
For the duration of the assigned timezone, a valid PIN code must be entered
after any card is presented. This overrides any PIN required option that may
be set for any group or user.
Any Card
For the duration of the assigned timezone, any card presented will be
granted access as long as it contains Track 2 data, even if it would not
normally be granted access.
Activate OP2
For the duration of the programmed timezone, the user programmable
output OP2
is active.
Activate OP3
For the duration of the programmed timezone, the user programmable
output OP3
is active.
Activate AUX
For the duration of the programmed timezone, the 1A auxiliary relay
output AUX
is active.
PIN Only
For the duration of the programmed timezone, the reader is disabled, and
access is granted only by entering a valid PIN.
PIN or Card
For the duration of the programmed timezone, either a valid PIN or a valid
Card will allow access.
Twin Users
While this timezone is active, two valid cards must be presented to gain
access. Used in high security applications where two people must be in the
room at the same time.
Normalise
During this timezone a door will revert to normal state, i.e.
Doors
requires valid card to gain access. Use this to ensure door is closed at certain
times in case it is left toggled open.
Communications
This menu allows the installer to configure how the controller communicates with externally
connected devices or over a network. It is used primarily to configure the communications mode
or address of the unit, or to specify log printer options.