![ACT ACTPRO 3000 ACCESS CONTROL UNITS Operating And Installation Instructions Download Page 19](http://html.mh-extra.com/html/act/actpro-3000-access-control-units/actpro-3000-access-control-units_operating-and-installation-instructions_2842160019.webp)
System Settings
The
System Settings
menu allows the installer to access a number of different configuration
menus controlling different aspects of the setup of the controller. Pressing the
✔
key toggles the
setting of a displayed option.
OPERATION
This menu allows the installer to select or de-select a number of options relating to the default
operation of the controller.
•
The
PIN Only
option allows reader-less operation using PIN codes that are directly entered on
the keyboard (or on an external keypad). 30,000 pin codes supported.
•
The
Learn
option allows users to use randomly coded cards. Almost any card with valid ISO
track 2 data may be used (for example bankcards) as well as some types of wiegand card.
•
The
Exit PIN’s
option requires pin codes to be entered before the user is allowed to exit.
•
The
User Limiting
option will prevent access to tracked users when the user limit is reached.
•
The
One-To-One
option allows any card number to be assigned to any of the 30,000 users.
•
The
Multiple
option allows users to have more than one card on the system.
DISPLAY
•
The
Backlight
option forces the keypad to be permanently illuminated, overriding the default
automatic operation, which is to operate only when a user menu has been entered.
•
The
Keypad Beep
option forces the keypad to make a short beep in response to any key being
pressed. This option is selected by default.
•
The
Show Status
option enables the displaying of continuous door status on the display. This
option is enabled by default.
•
The
Show Events
option enables the displaying of events on the display as they occur. This
option is enabled by default.
•
The
Handshake
option is used when a serial printer is connected. When selected, information
will only be sent to the printer when a positive signal is applied to the RX pin on the printer
port. This may be used to temporarily halt printing when the printer is disconnected or out of
paper.
•
The
Tech Bleep
option specifies that the ACTpro 2000 onboard buzzer will sound
intermittently if a technical fault (mains, tamper or door offline) condition exists.
Language
The ACTpro 3000 display supports the following languages English, Polish, French, Spanish,
Dutch and Italian. The language is selected from this menu.
PIN LENGTH
The length of PIN codes used in PIN Only and PIN & Card modes may be set between 4 and 9
digits. If a PIN length greater than six is set, then the length of the operator and installer codes
will increase to this length. (Leading zeros added to PIN).
FIRE DOORS
This function allows a group of doors (or all doors) to be configured for fire override. A 0Volt
signal from a fire alarm (or other) system is applied to the
AUX input on door 1.
This maintains
normal operation. When the 0Volt signal is removed, the selected doors are held open until the
0Volt signal is re-applied. Typically, a normally-closed relay on the fire panel, with the common
connected to 0Volts, is used for this purpose. Please note that this facility is present for
convenience only, it does not remove the need to have an alternate mechanical means of escape.
ACTpro 3000 Operating Instructions
Firmware Version 1.24
15