![ACT ACTPRO 3000 ACCESS CONTROL UNITS Operating And Installation Instructions Download Page 13](http://html.mh-extra.com/html/act/actpro-3000-access-control-units/actpro-3000-access-control-units_operating-and-installation-instructions_2842160013.webp)
AUX OUTPUT ON
The
AUX output on
function causes the auxiliary output relay to be energized. It will remain
energized until the output is explicitly switched off. The output may be used to control externally
connected equipment such as lights or heating.
AUX OUTPUT OFF
The
AUX output off
function causes the auxiliary output relay to be de-energized. The output may
be used to control externally connected equipment such as lights or heating.
User Tracking
The user tracking option allows the controller to remember which users are in or out of the defined
area. If antipassback or timed antipassback doors are assigned, then these define the tracking area,
however users will not be allowed to re-enter the area until they have been recorded as exiting, or
they may re-enter through a timed antipassback door after the timed antipassback period has
expired. If perimeter doors are assigned, then these define the tracking area, however users may
re-enter without restriction. If both are assigned, then the antipassback doors and the timed
antipassback doors define the tracking area.The
Users Present
output and
User Limit A & B
outputs operate on the tracking area.
LOG IN
This function manually enters a user into the area. An event is logged for tracking. This is typically
used when a user has forgotten their card. Manual login is not available if antipassback doors are
defined - card access MUST be used.
LOG OUT
This function manually removes a user from the area. An event is logged for tracking. This is
typically used when a user has forgotten their card or when they have violated antipassback
procedures and require entry.
CLEAR ALL
This function manually removes all users from the area. An event is logged for tracking. This is
typically used at the end of a day or week to remove any users from the system who have neglected
to use their cards when exiting.
Date/Time
The
Set Date/Time
function allows the operator to adjust the date and time on the controller’s
real-time clock. The built-in clock is normally accurate to within 60 seconds per month and will
occasionally need adjusting to maintain the accuracy of logged events.
The display will prompt the user to enter the correct year (1996-2020), month (1-12), date (1-31),
hour (0-23) and minute (0-59). The seconds will be zeroed. The prompt “
Set?
” is displayed on the
bottom line of the LCD. The clock will not actually be updated until the
✔
key is pressed, allowing
the operator to wait until the time is exactly correct. Any other key will exit without altering the
time.
The day of the week calculation and leap year adjustments are made automatically by the
controller’s internal clock, even if power is not present. ACTWin pro automatically changes the
controller time to match that of the PC.
ACTpro 3000 Operating Instructions
Firmware Version 1.24
9