ACTpro 3000 Access Control Units
Operating & Installation Instructions
Access Control Technology
18-00035
Page 1: ...ACTpro 3000 Access Control Units Operating Installation Instructions Access Control Technology 18 00035 ...
Page 2: ... Names 5 Access Rights 5 Assign Options 6 Assign PINs 6 Timed Antipassback 7 System Log 7 Display Log 7 Print Log 7 Recommended Printer Printer Settings 8 Filter Log 8 Control Door 8 Lock Door 8 Unlock Door 8 Normalise Door 8 Pass Door 8 AUX output on 9 AUX output off 9 User Tracking 9 Log in 9 Log out 9 Clear All 9 Set Date Time 9 Time Zones 10 Set Holidays 12 Issue Number 12 Change PIN 12 INSTAL...
Page 3: ...1 21 Site Code 2 21 Card Format 21 Change PIN 22 Factory Default 22 Diagrams ACTpro 3000 Standalone Configuration 23 ACTpro 100 Door Station Installation 24 ACTpro 200 Door Station Installation 25 Wiring for Entry Exit Readers 26 ACTpro 3000 PC Printer and Modem Cables 27 Interlock Configuration 28 Fire Override Configuration 28 ACTWin pro Configuration 29 ACT 4 Line Network Wiring 30 ACT Single L...
Page 4: ...ttp www accesscontrol ie E mail sales accesscontrol ie Copyright 2008 Access Control Technology Ltd Rev 2 Access Control Technology ACTpro 3000 ACTpro 100 200 ACTpro IOM ACT Net IF 1 ACT Net IF 4 ACT 56 Modem Controller Door Expander I O Module Single Channel RS485 interface Four channel interface 56k modem Ordering Information ...
Page 5: ...ctions are accessed via two six digit codes The first code is for the Operator who is responsible for the day to day administration of the system adding and deleting users setting names and assigning time zones etc The second code is for the Installer who performs the initial configuration of the system and decides on communications settings interfaces and modes of operation Default Codes Operator...
Page 6: ...ssback each group System Log Display Log Show the system log on the display Print Log Print the system log on an attached serial printer Filter Log Prevent events entering the system log Control Door Lock Door Lock door prevent all cards from opening it Unlock Door Unlock door relay is activated so cards are not required Normalise Door Set a door back to normal operation Pass Door Momentarily open...
Page 7: ... any displayed or printed log events involving this user Pressing the key selects text entry mode ASSIGN GROUPS The Assign Groups function allows a user or range of users to be assigned to a group Any of the 30 000 users can be assigned to one of 1024 groups The Display will show the user number on the top line and the group that that user is assigned to on the bottom line The displayed user numbe...
Page 8: ...N is never shown on the display In PIN Only operation this is the PIN that that user must enter to gain access In this case the PIN must be unique In PIN Card operation this is the PIN that must be entered after the user has presented a card to the reader If a PIN for a user is not set then the relevant group PIN may be used instead PIN Card only LEARN In Learn Mode all 30 000 users may be allocat...
Page 9: ...nd will not be allowed entry to the protected area even if the individual users are enabled ASSIGN NAMES The Assign Names function allows a 16 character textual name to be assigned to each group Pressing the key selects text entry mode The group name is entered or deleted in exactly the same fashion as for individual user names ACCESS RIGHTS The Access Rights function allows up to 8 timezone and d...
Page 10: ...essing the key allows the options to be altered When changing options the 0 key advances to each option and the key selects or deselects the displayed option Option Description 2 Activate O P 2 The general purpose output OP2 is activated for its programmed duration when users in this group are granted access 3 Activate O P 3 The general purpose output OP3 is activated for its programmed duration w...
Page 11: ... to stop the printout is given it will not be displayed The PIN must then be re entered for verification The PIN will be accepted as long as it does not conflict with any existing PIN or duress PIN The actual PIN is never shown on the display If set a PIN directly assigned to a user will take priority over this PIN TIMED ANTIPASSBACK The antipassback feature is designed to stop users giving their ...
Page 12: ...ered out on certain doors Normally all doors are allowed but the user may prevent certain doors from reporting events ACTpro 3000 Operating Instructions Firmware Version 1 24 8 Control Door The Control Door menu allows the operator to control the door or externally connected equipment such as lighting or heating LOCK DOOR The Lock Door function causes the door relay to be de energized The bottom l...
Page 13: ...en their card Manual login is not available if antipassback doors are defined card access MUST be used LOG OUT This function manually removes a user from the area An event is logged for tracking This is typically used when a user has forgotten their card or when they have violated antipassback procedures and require entry CLEAR ALL This function manually removes all users from the area An event is...
Page 14: ...e is set then these dates must be programmed The GMT function must be set to specify the difference between local time and GMT This is the difference between the local time and GMT during the winter time period Specifying this correctly means that change to summer and winter time will occur at 1 00 am GMT regardless of the local time If the clock is changed on the same date as Summer Winter then t...
Page 15: ...Changing days holidays Wednesday 0 for next day holiday TWTF 1 4 to select deselect when done 4 Changing time period Period 0 9 to set time 08 30 17 00 for next minute hour when done In addition the timezone may be assigned a name or all time periods cleared quickly by highlighting and selecting the or symbols respectively timezone may be selected using the 0 key or directly by entering the timezo...
Page 16: ... be given cards with an issue level of 255 which will always work Note Issue numbering is usually only possible with standard ACT site coded cards Change PIN The Change PIN function allows a different PIN to be configured for the operator The user will be prompted to enter a new six digit code it will not be displayed The PIN must then be re entered for verification The PIN will be accepted as lon...
Page 17: ...Internal Doors Define Internal doors Tracking Reset Set time for auto reset auto logout User Limits Set user limits A B Outputs Door 1 Define door 1 output special functions Door 2 Define door 2 output special functions Door Settings Operation Push Button Door release button enabled Lock Saver Relay de energized as door opens Chime Buzzer sounds as door opens Guest Button on external keypad fires ...
Page 18: ...malised Assign Name Assign a name to a door Communications Set Address Set the network address of this door Direct Conn Specifies that this controller is connected directly to a PC Comms Speed Select communications speed Slave Mode Specifies that this controller is a slave under ACT5000pc No Hist Log Disables the reporting of offline log events in slave mode Print All Enables real time logging on ...
Page 19: ...splay This option is enabled by default The Show Events option enables the displaying of events on the display as they occur This option is enabled by default The Handshake option is used when a serial printer is connected When selected information will only be sent to the printer when a positive signal is applied to the RX pin on the printer port This may be used to temporarily halt printing when...
Page 20: ... as Timed Antipassback doors are displayed as Timed Antipassback doors define the tracking area Users are allowed entry to the area only if they have previously exited or after the Timed Antipassback period has expired The Timed Antipassback period is defined on a user group basis Note If a door is specified as an Antipassback door and as a Timed Antipassback door then the door will operate as a T...
Page 21: ...ranted or denied The Exit PIR option will keep the door open while the external push button contact is closed This allows a PIR to be used as the exit switch The Failsafe option sets the door relay to be normally energised This means that the door will open if the power supply to the controller fails The Toggle Relay option allows the door to be toggled open or closed by users with the Toggle Rela...
Page 22: ...LED on the Reader will Flash PIN Required For the duration of the assigned timezone a valid PIN code must be entered after any card is presented This overrides any PIN required option that may be set for any group or user Any Card For the duration of the assigned timezone any card presented will be granted access as long as it contains Track 2 data even if it would not normally be granted access A...
Page 23: ...9600 and 19200 baud are permitted on the single line RS485 networked interface 9600 baud only is permitted on the ACT 4 Line RS485 interface SLAVE MODE This option selects slave mode operation as part of an ACT5000pc network While the controller is switched into slave mode and all card events are transmitted to the network master for validation The controller itself will not make any decisions on ...
Page 24: ...or should be asked for a suitable TCP Port Number NETWORK MASK The Network Mask is used by the ACTpro 3000 firmware to separate the local subnetwork address from the rest of a given IP address The network administrator can provide this information DEFAULT GATEWAY The Default Gateway Default Route is the IP address of the router that connects the network to other networks or the Internet The networ...
Page 25: ...0 00 CARD FORMAT When Active is set to YES the controller will recognize cards with a non standard custom format The card information must be encoded using ISO ABA Track 2 format and may contain from 2 to 37 digits When Check All is set to YES the controller will also allow cards encoded with one of its standard built in formats This could be used for example in a transitional period while older l...
Page 26: ...nter the ACT default Site Code 10 2770 09 When asked to default controller hit the key to default It is always a good idea to factory default a new controller prior to initial configuration or if the controller software has been changed or upgraded After entering this Menu a door must be selected where the test is performed and then the Swipe Card is displayed on the second line The card should th...
Page 27: ...de energised locks are required use the N O relay contacts Note If the Mains Present or Door Contact inputs are not used they should be linked to 0V Door 2 Release Button Door 2 Contact Release Button Door 1 Door 1 Contact Card Proximity or Pin Reader Door 2 Card Proximity or Pin Reader Door 1 Important Always Place Varistor Across Lock Terminals Door 2 Door 1 12V DC Power Supply 12V 0V DC Cable 8...
Page 28: ... OFF OFF ON OFF OFF 05 OFF OFF ON OFF ON 06 OFF OFF ON ON OFF 07 OFF OFF ON ON ON 08 OFF ON OFF OFF OFF 09 OFF ON OFF OFF ON 10 OFF ON OFF ON OFF 11 OFF ON OFF ON ON 12 OFF ON ON OFF OFF 13 OFF ON ON OFF ON 14 OFF ON ON ON OFF 15 OFF ON ON ON ON 16 ON OFF OFF OFF OFF Power Supply Unit 12V 0V Max len 30M Total Length max 1 4km For Clock Data Readers wire exit reader in parallel but leave it s sense...
Page 29: ... the Red LED will flash rapidly If there is a problem it will flash slowly about once a second Green LED will flash if an event occurs on the ACTpro200 www accesscontrol ie OP3 OP2 0V AUX INPUT DC2 PB2 OP3 OP2 0V AUX INPUT DC2 PB2 NC C NO NC C NO NO C NC NO C NC 12V GREEN RED 0V 5V DATA CLOCK SENSE TAMPER 5A 250VAC 5A 30VDC 5A 250VAC 5A 30VDC 5A 250VAC 5A 30VDC 5A 250VAC 5A 30VDC Door Address Exam...
Page 30: ...ders White Green Blue Red Black Brown Yellow Orange SENSE CLOCK DATA 1 DATA DATA 0 5v 0v RD GREEN Buzzer Control Wiring for Clock and Data Wiegand Reader The standard wiring colours for ACTpro Proximity and Pin readers is shown above Readers may be a maximum of 30m from the controller when powered from 5V and a maximum of 100m when powered from 12V The 5V reader supply on ACT controllers is normal...
Page 31: ...ler ACTpro 3000 Serial Printer 0V TX RX Max cable length is 5m using standard alarm cable or 30m using twin twisted pair use 0V in each pair 0V TX RX DB9 Female Rear View 1 2 3 4 5 6 7 8 9 Direct Connection Cable PC COM Port to Controller Max cable length is 5m using standard alarm cable or 30m using twin twisted pair use 0V in each pair DB25 Male Rear View 7 20 3 Serial Printer Cable ACTpro 3000 ...
Page 32: ...ELAY 2 N C N O C AUX RLY 2 N C N O C DC FIRE N C N O C FIRE ALARM PANEL While the 0V signal is maintained at the AUX input on Door 1 the doors in the Fire Doors group maintain normal operation When the 0V signal is removed the doors are opened and remain open until the 0V is restored To set the Fire Doors group go to Installer Menu System Settings Fire Doors From ACTWin pro go to View Options Door...
Page 33: ...ove Set to No if it is a networked system For more than one controller an RS 485 Network Interface is required 4 Connect the controller s to the PC 5 From ACTWin pro configure a new database 6 Follow the database creation wizard 7 Ensure that Comms is set up correctly 8 Connect to the controllers Click here to configure Comms Select if Direct Connect or Networked Select if Serial Port or Modem or ...
Page 34: ... ACTpro 3000 ACTpro 1000 ACTpro 2000 Shield Network printer Timekeeper Lithium Battery C 1 2 C 1 2 C 1 2 C 1 2 AC RS485 RS485 RS485 232 Interface 232 Interface Converter Converter LED2 LED3 To next door A NETWORK 1 B A B A B DTR RX TX 0V A B 0V DTR RX TX 0V A B 0V TX RX A B 0V DOORS SERIAL PRINTER DTR RX TX 0V A B 0V Shield 120R Resistor on last node C SHIELD 1 B 2 A RS232 PORT SCN Pin 5 C Pin 7 D...
Page 35: ...nnect up to 32 controllers To next Controller NETWORK 1 DOORS SERIAL PRINTER DTR RX TX 0V A B 0V Shield A B 0V NETWORK PRINTER ACTWin Software 12V DC Power Supply 300mA 12V 0V 1 12V 2 0V Shield 3 B 4 A Pin Function RS 485 Bus RS 232 1 From the Controller keypad Enter Installer Menu Communications and set a unique address for each controller on the network Set Direct Connect to No 2 From ACTWin pro...
Page 36: ...ACTpro 3000 Operating Instructions Firmware Version 1 24 32 ACTpro 3000 Hub Operation ...
Page 37: ...0 ACTpro 3000 AS HUB CONTROLLER RS485 Network cable use either 1 Single shielded twisted pair Beldem 9501 or similar 2 CAT5 Cable A B must share the same twisted pair ACTWin Software RS232 Direct Connect Cable NET2 Flashing NET2 Led shows activity on the RS485 Network ACTpro 3000 Hub PC connection 1 RS232 Direct Connect 2 TCP IP over Ethernet LAN RS485 BUS RS485 line may be up to 1 4 km in length ...
Page 38: ... Set up remote controller s in the Controller View Set the location as the remote site name 6 The controller s will appear under the remote site name in the System View window 7 Double click on the telephone icon beside the remote site name in System View window 8 Modem will now contact remote Site and connect to the controller s 9 To finish the call click the disconnect button on ACTWin pro ACTWi...
Page 39: ...strator 3 Again If the ACTpro 3000 and the PC running ACTWinPro are on different subnetworks You should confirm with the Network Administrator that You want to use TCP Port Number 10001 4 Once the LAN Administrator has supplied the information needed enter this data via the ACTpro 3000 keypad Installer Menu TCP IP Settings see page 22 5 Connect the ACTpro 3000 to the Local Area Network the LINK Le...
Page 40: ...V GND 12V DO D1 GND EN Link Sense to 0V Use Belden 9502 or equivalent Receiver may be maximum of 100metres from controller 12V PSU 0V Receiver D1 Recevier D0 Not Connected Recevier 0V Not Connected Not Connected SENSE CLOCK DATA 5V 0V RED GREEN Wiring Connections All Channels Enabled Switches 1 to 4 ON Standard ISO Track 2 Start Sentinel 16 Digits Seperator End Sentinel LRC Prastel MRRE Receiver 3...
Page 41: ...m will be Arm Disarmed from 2 Enter the installer Menu and select the Door Settings submenu Then select the Door number of the reader that User will arm and disarm from 3 In the Alarm section of Door Settings set the ARM Intruder option to Yes 4 If the Alarm Panel provides a signal to indicated the arm disarm status then in the Operation section of the Door settings set the Monitor Arming Option t...
Page 42: ...he OFF position The two LED s will illuminate for about 2 sec The correct switch settings may then be set If the Mains Present or Door Contact inputs are not used they should be linked to 0V LED Functionality Red LED indicates the status of communications with the Controller While online to the controller the Red LED will flash rapidly If there is a problem it will flash slowly about once a second...
Page 43: ...o 100 ACTpro 100 ACTpro 100 ACTpro 100 ACTpro100 RS485 ACTpro 100 ACTpro 100 Door 16 Door 16 Door 4 Door 4 Door 4 Door 3 Door 3 Door 3 Door 1 Door 1 Door 1 Door 1 Door 1 Door 1 Door 2 Door 2 Door 2 Door 2 Door 2 Door 2 Modem Modem 485 Converter RS 485 Line 4 RS 485 Line 3 RS 485 Line 2 LAN RS232 4 Line Interface RS232 PSTN RS232 Up to 32 Controllers RS485 Line 1 Max length 1 4 Km ACTpro 3000 Syste...