BusWorks® 965EN Module User’s Manual Modbus TCP/IP mV/TC Input
___________________________________________________________________
_______________________________________________________________________________________
Acromag, Inc. Tel:248-295-0880 Fax:248-624-9234 Email:
5
TB1
11
46
13
44
14
43
16
41
TB4
21
36
22
35
24
33
25
32
IN
5
-
IN
0
+
IN
4
-
IN
0
-
IN
4
+
IN
1
-
T
B
4
IN
2
-
G
N
D
IN
3
+
D
C
-
T
B
3
C
R S T
D FT
LIN K
12
45
TB2
15
42
23
26
31
34
L
A C T
S T
3
.7
5
(9
5
.3
)
T
B
1
C JC -0
IN
5
+
3.90
(99.1)
IN
1
+
T
B
2
T
B
2
IN P U TS 0, 1
C JC -2
IN
2
+
IN
3
-
IN P U TS 2, 3
D
C
+
P W R
1.05
(26.7)
4
.6
8
(1
1
8
.9
)
R U N
TB3
2
.3
4
(5
9
.4
)
"T" RAIL DIN MOUNTING
DIN EN 50022, 35mm
E TH E R N E T
Acromag
IN P U TS 4, 5
C JC -1
4.35
(110.5)
NOTE: Dimensions Are INCHES (MILLIMETERS).
MODEL 965EN ENCLOSURE DIMENSIONS
(Model 965EN-4006 Only)
Model 965E N-4006 S hown
(965E N-4004 S im ilar )
R S T
11
46
12
45
14
43
15
42
22 23
25
32
26
31
A C T
S T
IN
5
-
IN
5
+
IN
0
-
IN
4
+
IN
1
+
T
B
4
T
B
2
T
B
2
IN
2
+
IN
3
+
D
C
-
IN
3
-
D
C
+
LIN K
TB1
13
16
44
41
21
24
LS D
33
MS D
T
B
1
IN
0
+
IN
1
-
IN P U TS 0, 1
IN
4
-
C JC -2
TB4
IN
2
-
IN P U TS 2, 3
C JC -1
G
N
D
P W R
S LA V E
A D D R E S S
(H E X )
T
B
3
TB3
E TH E R N E T
D FT
R U N
TB2
(PLUG-IN TYPE)
TERMINAL BLOCKS
RJ45 ETHERNET
CONNECTOR
C JC -0
ETHERNET ACTIVITY
LED (YELLOW) AND
LINK LED (GREEN)
Acromag
IN P U TS 4, 5
RUN/PWR LED (GREEN)
REMOVABLE
RESET/DEF ADDRESS
TOGGLE SWITCH:
TOGGLE RIGHT TO RESET
TOGGLE LEFT TO SET
DEFAULT ADDRESS
MODULE STATUS
LED (YELLOW)
Model 965E N-4006 S hown
(965E N-4004 S im ilar )
(Model 965PB-2006 Only)
IN
4
-
44
41
36
33
PWR
N
E
T
W
O
R
K
13
IN
0
+
16
IN
1
-
21
24
IN
2
-
T
B
3
T
B
1
G
N
D
INPUTS 4, 5
IN
5
-
46
43
45
RX
CJC-2
35
42
DC-
DC+
32 31
34
TB1
11
14
12
IN
0
-
CJC-0
TB2
22
15
TX
IN
1
+
CJC-1
5V/3V
TB4
T
B
4
25
23
26
IN
3
+
IN
2
+
IN
3
-
INPUTS 2, 3
DC
PWR
IN
4
+
IN
5
+
T
B
2
T
B
2
ANALOG I/O
ANALOG I/O
INPUTS 0, 1
ANALOG I/O
TRANSFORMER
TB3
965EN
ISOLATION
DIAGRAM
TRANSFORMER
(Model 965EN-4006 Only)
The toggle switch is used to toggle the module into or out of Default Mode
(toggle left), or to reset the module (toggle right). In Default Communication
Mode, the yellow ST LED blinks slowly and the module assumes a fixed
static IP address of “128.1.1.100”, a default subnet mask of “255.255.255.0”,
a default username of
“User”, and a default password of “password00”.
MOUNTING AND
DIMENSIONS
Unit mounts to “T” type DIN
rails (35mm, type EN50022).
Units may be mounted side-
by-side on 1-inch centers.
WARNING: IEC Safety
Standards may require that
this device be mounted within
an approved metal enclosure
or sub-system, particularly for
applications with exposure to
voltages greater than or equal
to 75VDC or 50VAC.
CONTROLS &
INDICATORS
Green Run LED is ON if power
is on and will blink in “wink” ID
mode.
Yellow ST LED blinks ON/OFF
if module is in default mode
and stays ON if an input is out
of range.
Green LINK LED ON if auto-
negotiation has successfully
established a connection.
Yellow ACT LED signals PHY
network Activity (busy).
ISOLATION BARRIERS
Dashed Lines denote isolation
barriers.
The input circuit, network, and
power circuit are isolated from
each other for safety and noise
immunity.