56
Activation of the
OUTPUT for a pre-set
time after pressing the
F2 key on the uniphone
or after selecting the
code preceded by the
double pressing the key
button
Gate control using standard
two wires from the camera
and code from the keypad
IN=x (x: has no
effect)
OUT=t (t: time from
1 to 255 s) NrF=2
Control from
uniphone works only
during a call
CDNP6 only:
Activating the E-
lock without making
a call
Pick up the handset and
press the "key" button three
times
For INS-UP720MR and INS-
MPR, press once the
"key” button without lifting
the handset
IN=x (x: has no
effect)
OUT=0
NrF=3
Works only for P1 port,
no need to connect the
CDN-I/O module
CDNP6 only:
Activation of the
OUTPUT for a pre-
set time without
making a call
Pick up the handset and
press the “key” button three
times
For INS-UP720MR and INS-
MPR, press the “key” button
once
IN=x (x: has no
effect)
OUT=t (t: time from 1
to 255 s) NrF=3
Works only for P1 port
Activation of the
OUTPUT for a pre-set
time after pressing any
key on the unit/panel or
expansion module
Automatic light switch on in
front of the entrance / on
the staircase
IN=x (x: has no
effect)
OUT=t (t: time from 1
to 255 s) NrF=3
Works only for P2 port
Example of the CDN-I/O module settings:
Example settings:
Settings
Remar
ks
Opening the second gate
using the code ("double
key"), using the F2 button
on the uniphone and
(CDNP6 only) opening the
gate without making a call
(pick up the handset and
press the "key" button three
times)
Port P1: N=x
(x: has no
effect)
OUT=0
NrF=3
Port P2:
IN=x (x: has no
effect)
OUT=t (t: time from
1 to 255 s) NrF=2
Connect outputs of port P1 and P2 in
parallel ("N" with "N", "NO" with "NO" )
For INS-UP720MR and INS-MPR it is
enough to press the "key" once
without lifting the handset
Opening the second gate
using the code ("double
key"), using the F2 button
on the uniphone and
(CDNP6 only) activating the
E-lock without making a call
(pick up the handset and
press the "key" button three
times)
Port P1:
IN=x (x: has
no effect)
OUT=t (t:
time from 1
to 255 s)
NrF=3
Port P2:
IN=x (x: has no
effect)
OUT=t (t: time from
1 to 255 s) NrF=2
For INS-UP720MR and INS-MPR it is
enough to press the "key" once
without lifting the handset
Opening the second gate
using the code ("double
key"), using the F2 button on
the uniphone without making
a call via the third wire to the
uniphone (only INS-720M,
INS-720MR)
Port P1:
IN=0
OUT=t (t: time
from 1 to 255
s) NrF=0
Port P2:
IN=x (x: has no
effect)
OUT=t (t: time from
1 to 255 s) NrF=2
Connect outputs of port P1 and P2 in