35
In a multi-panel system, the ringtone disabling works only on the panel on which
ringtones were set.
The receiver in a disconnected apartment will still emit the door opening signal
when opening using the access code (use P4 menu to disable it).
Now the value “
Nbr ?
” is the new call number, to be selected with the keypad,
since the unit operates as per the settings in P9 (offset, range) and automatically
calculates the uniphone physical address.
NOTE!
- When changing the number of ringtones simultaneously for all
apartments, ringtones to the previously deactivated apartments will be
reactivated.
When the unit is reset to factory settings, 2 ringtones are set for all apartments.
P4 TURNING THE DOOR OPENING SIGNAL ON - OFF IN THE APARTMENT
OpInf
After opening the door with an individual access code (or with an RFID proximity
card - CDN-ACC module) a short, triple beep is emitted in the apartment to
which the code (card) is assigned. Program P4 can be used to disable or enable
this signal. By default the signal is enabled.
Enter the program, wait for "
Nbr ?
” to be displayed, then enter the number of
the apartment for which the door opening signal is to be turned on or off (or
enter "
0
" if the change is to apply to all apartment) and confirm with the "
key
"
button. When changing the settings for selected apartment, the current setting
will appear briefly on the display -
“
On
” if the signal is on or “
Off
” if the signal is
off, and "
All
" will appear if the setting is being done for all apartments. While
"
????
" is being displayed, enter "1" to enable the door opening signal -
“
On
”
will appear briefly on the display or enter “
0
” to disable the door opening signal -
“
Off
” will appear briefly on the display (pressing the "#" key will exit the function
without saving the change). Then the unit will display "
Ready
”; settings are now
stored in unit’s memory.
Now the value “
Nbr ?
” is the new call number, to be selected with the
keypad, since the unit operates as per the settings in P9 (offset, range)
and automatically calculates the uniphone physical address.