38
Delay of E-lock activation after closing the terminals of additional input is also
available in slave units - program P12.
P7 CHANGING THE INSTALLER’S PASSWORD
IPass
This program is used to set a new 4-
digit installer’s password (installer
programming access password). The default password is "0000”. This is how to
set a new installer’s password to 5482.
Enter the program,, wait for “Digit1” to be displayed - then enter the first digit of
the password: "5", then “Digit2” is displayed - enter the second digit:
"4", then “Digit3” is displayed - enter the third digit: "8" and the “Digit4” is displayed
- enter the fourth digit: 2 "
Ready
" is displayed and the new password is stored in
memory. Use the "#" button to exit the function without changing the password.
NOTE!
Installer’s password cannot be restored!!! In order to set the password to
1507 0000, the unit settings must be erased, which means that all previously
changed settings are lost.
P8 VERIFYING CARD ASSIGNMENT TO APARTMENTS
Fobs
The program is used verify proximity cards and key fobs - to which apartments
they are assigned and what their sequence numbers are.
After entering the program, the unit displays "====” and now when a card or key
fob is brought closer to the CDN - ACC reader module, the unit will display the
number of the apartment to which the card (key fob) is assigned and then the
sequence number of the card (key fob) in this aparment. Use the "#" button to
turn the function off.
P9 CALLING RANGE PARAMETERS
Param
This program is used to set the parameters for dialling and range of call
numbers. Three parameters can be set:
- "
Mov
”
ringing number offset (by default "0") - the offset value determines
the difference between the dialled number on the unit keypad and the physical
address set in the uniphone.
- “
From
”
first supported call number (by default "1"),